49.9K | 50K | 60K | 61K
IP66 protection level
AC&DC SPD type II, always guarding the inverter
AFCI optional
Smart IV Curve scan for early panel diagnosis
Robust back-up ability, switch over time <10ms, up to 150% EPS output for 10s
Support off-grid operation
Maximum 200% PV input
Maximum 40A input current per MPpT, support high power solar panel
AI ready, forecasting solar generation and load consumption, smart energy management strategy*
VPP ready, SolaX cloud supports resource aggregator (2030.5, OpenADR )
Support smart scene function, intelligent loads management(e.g., Heat pump, EV charger)*
Micro-grid ready, supporting a variety of scenarios, both on-grid and off-grid, balancing power between PCS and Hybrid in real time
Support 7x24h scheduling mode
Support Wireless meter solution
Dual independent battery ports are ready to expand more capacity
It offers 24/7 smart energy management, utilizing AI to forecast solar generation and load consumption, with VPP readiness and intelligent scene functions for optimal energy use. It delivers high efficiency and reliability with a switch-over time of less than 10ms and up to 150% EPS output for 10 seconds, supporting off-grid operations. Additionally, it is highly cost-effective, supporting up to 200% PV input and 40A input current per MPPT, making it ideal for high-power solar panels and ensuring maximum energy savings and efficiency.
Category | X3-AELIO-49.9K | |
DC Side | Max. PV input power [kW] | 100 |
Max. PV input voltage [V] | 1000 | |
Start-up voltage [V] | 200 | |
Nominal input voltage [V] | 650 | |
MPPT voltage range [V] | 160-950 | |
No. of MPP trackers / Strings per MPP tracker | 5 (2 per MPPT) | |
Max. input current per MPPT [A] | 40 | |
Max. input short circuit current per MPPT [A] | 50 | |
AC Side | Rated AC output power [kW] | 49.9 |
Rated AC output current [A] | 72.3 | |
Max. AC output apparent power [kVA] | 49.9 | |
Max. AC output current [A] | 83.2 | |
Nominal AC voltage [V] | 3P4W, 400/230, 380/220 | |
Rated AC grid frequency [Hz] | 50 / 60 | |
Adjustable Power Factor range | 1 (0.8 Leading ~ 0.8 Lagging) | |
THDi (Rated power) [%] | < 3 | |
Battery Side | Battery type | Lithium - ion |
Battery voltage range [V] | 180 - 820 | |
Max. charge / discharge current [A] | 160 (80x2) | |
EPS Output (with battery) | Peak apparent AC power [kVA] | 49.9 |
Nominal voltage [V]; Frequency [Hz] | 3P4W, 400/230V, 380/220V; 50/60HZ | |
Max. output continuous current [A] | 72 | |
Switch time [ms] | < 10 | |
General | Max. efficiency [%] | 98 |
European weighted efficiency [%] | 97.2 | |
Ingress protection | IP66 | |
Operating ambient temperature range [°C] | - 35 ~ 60 | |
Max. operating altitude [m] | < 3000 | |
Relative humidity [%] | 0 ~ 100 | |
Typical noise emission [dB] | < 70 | |
Dimensions (W×H×D) [mm] | 820 × 670 × 257 | |
Net weight [kg] | < 100 | |
Cooling concept | Smart air cooling | |
Communication interfaces | RS485, CAN(BMS), CAN, USB, DI, DO, DRM | |
Display | LCD (optional) | |
Power Consumption | Standby consumption (night) [W] | < 10 |
Protection | Over/under voltage protection | Yes |
DC isolation protection | Yes | |
DC reverse-polarity protection | Yes | |
Grid monitoring | Yes | |
DC injection monitoring | Yes | |
Back feed current monitoring | Yes | |
Residual current detection | Yes | |
Anti-islanding protection | Yes | |
Over temperature protection | Yes | |
SPD (DC/AC) | Type II/Type II | |
Arc-fault circuit interrupter (AFCI) | Optional | |
Standard | Safety | EN/IEC 62109-1/-2 |
EMC | EN 61000-6-1/2/3/ 4, EN 61000-3-11/12, EN 55011, IEC 62920 | |
Cetification | VDE4105, G99, AS4777, EN50549, CEI 0-21, IEC61727, PEA/MEA, NRS-097-2-1, RD1699, TOR |
Category | X3-AELIO-50K | |
DC Side | Max. PV input power [kW] | 100 |
Max. PV input voltage [V] | 1000 | |
Start-up voltage [V] | 200 | |
Nominal input voltage [V] | 650 | |
MPPT voltage range [V] | 160-950 | |
No. of MPP trackers / Strings per MPP tracker | 5 (2 per MPPT) | |
Max. input current per MPPT [A] | 40 | |
Max. input short circuit current per MPPT [A] | 50 | |
AC Side | Rated AC output power [kW] | 50 |
Rated AC output current [A] | 72.5 | |
Max. AC output apparent power [kVA] | 55 | |
Max. AC output current [A] | 83.3 | |
Nominal AC voltage [V] | 3P4W, 400/230, 380/220 | |
Rated AC grid frequency [Hz] | 50 / 60 | |
Adjustable Power Factor range | 1 (0.8 Leading ~ 0.8 Lagging) | |
THDi (Rated power) [%] | < 3 | |
Battery Side | Battery type | Lithium - ion |
Battery voltage range [V] | 180 - 820 | |
Max. charge / discharge current [A] | 160 (80x2) | |
EPS Output (with battery) | Peak apparent AC power [kVA] | 55 |
Nominal voltage [V]; Frequency [Hz] | 3P4W, 400/230V, 380/220V; 50/60HZ | |
Max. output continuous current [A] | 83.6 | |
Switch time [ms] | < 10 | |
General | Max. efficiency [%] | 98 |
European weighted efficiency [%] | 97.2 | |
Ingress protection | IP66 | |
Operating ambient temperature range [°C] | - 35 ~ 60 | |
Max. operating altitude [m] | < 3000 | |
Relative humidity [%] | 0 ~ 100 | |
Typical noise emission [dB] | < 70 | |
Dimensions (W×H×D) [mm] | 820 × 670 × 257 | |
Net weight [kg] | < 100 | |
Cooling concept | Smart air cooling | |
Communication interfaces | RS485, CAN(BMS), CAN, USB, DI, DO, DRM | |
Display | LCD (optional) | |
Power Consumption | Standby consumption (night) [W] | < 10 |
Protection | Over/under voltage protection | Yes |
DC isolation protection | Yes | |
DC reverse-polarity protection | Yes | |
Grid monitoring | Yes | |
DC injection monitoring | Yes | |
Back feed current monitoring | Yes | |
Residual current detection | Yes | |
Anti-islanding protection | Yes | |
Over temperature protection | Yes | |
SPD (DC/AC) | Type II/Type II | |
Arc-fault circuit interrupter (AFCI) | Optional | |
Standard | Safety | EN/IEC 62109-1/-2 |
EMC | EN 61000-6-1/2/3/ 4, EN 61000-3-11/12, EN 55011, IEC 62920 | |
Cetification | VDE4105, G99, AS4777, EN50549, CEI 0-21, IEC61727, PEA/MEA, NRS-097-2-1, RD1699, TOR |
Category | X3-AELIO-60K | |
DC Side | Max. PV input power [kW] | 120 |
Max. PV input voltage [V] | 1000 | |
Start-up voltage [V] | 200 | |
Nominal input voltage [V] | 650 | |
MPPT voltage range [V] | 160-950 | |
No. of MPP trackers / Strings per MPP tracker | 6 (2 per MPPT) | |
Max. input current per MPPT [A] | 40 | |
Max. input short circuit current per MPPT [A] | 50 | |
AC Side | Rated AC output power [kW] | 60 |
Rated AC output current [A] | 87 | |
Max. AC output apparent power [kVA] | 66 | |
Max. AC output current [A] | 100 | |
Nominal AC voltage [V] | 3P4W, 400/230, 380/220 | |
Rated AC grid frequency [Hz] | 50 / 60 | |
Adjustable Power Factor range | 1 (0.8 Leading ~ 0.8 Lagging) | |
THDi (Rated power) [%] | < 3 | |
Battery Side | Battery type | Lithium - ion |
Battery voltage range [V] | 180 - 820 | |
Max. charge / discharge current [A] | 160 (80x2) | |
EPS Output (with battery) | Peak apparent AC power [kVA] | 66 |
Nominal voltage [V]; Frequency [Hz] | 3P4W, 400/230V, 380/220V; 50/60HZ | |
Max. output continuous current [A] | 100.3 | |
Switch time [ms] | < 10 | |
General | Max. efficiency [%] | 98 |
European weighted efficiency [%] | 97.2 | |
Ingress protection | IP66 | |
Operating ambient temperature range [°C] | - 35 ~ 60 | |
Max. operating altitude [m] | < 3000 | |
Relative humidity [%] | 0 ~ 100 | |
Typical noise emission [dB] | < 70 | |
Dimensions (W×H×D) [mm] | 820 × 670 × 257 | |
Net weight [kg] | < 105 | |
Cooling concept | Smart air cooling | |
Communication interfaces | RS485, CAN(BMS), CAN, USB, DI, DO, DRM | |
Display | LCD (optional) | |
Power Consumption | Standby consumption (night) [W] | < 10 |
Protection | Over/under voltage protection | Yes |
DC isolation protection | Yes | |
DC reverse-polarity protection | Yes | |
Grid monitoring | Yes | |
DC injection monitoring | Yes | |
Back feed current monitoring | Yes | |
Residual current detection | Yes | |
Anti-islanding protection | Yes | |
Over temperature protection | Yes | |
SPD (DC/AC) | Type II/Type II | |
Arc-fault circuit interrupter (AFCI) | Optional | |
Standard | Safety | EN/IEC 62109-1/-2 |
EMC | EN 61000-6-1/2/3/ 4, EN 61000-3-11/12, EN 55011, IEC 62920 | |
Cetification | VDE4105, G99, AS4777, EN50549, CEI 0-21, IEC61727, PEA/MEA, NRS-097-2-1, RD1699, TOR |
Category | X3-AELIO-61K | |
DC Side | Max. PV input power [kW] | 121 |
Max. PV input voltage [V] | 1000 | |
Start-up voltage [V] | 200 | |
Nominal input voltage [V] | 650 | |
MPPT voltage range [V] | 160-950 | |
No. of MPP trackers / Strings per MPP tracker | 6 (2 per MPPT) | |
Max. input current per MPPT [A] | 40 | |
Max. input short circuit current per MPPT [A] | 50 | |
AC Side | Rated AC output power [kW] | 61 |
Rated AC output current [A] | 88.4 | |
Max. AC output apparent power [kVA] | 66 | |
Max. AC output current [A] | 101.7 | |
Nominal AC voltage [V] | 3P4W, 400/230, 380/220 | |
Rated AC grid frequency [Hz] | 50 / 60 | |
Adjustable Power Factor range | 1 (0.8 Leading ~ 0.8 Lagging) | |
THDi (Rated power) [%] | < 3 | |
Battery Side | Battery type | Lithium - ion |
Battery voltage range [V] | 180 - 820 | |
Max. charge / discharge current [A] | 160 (80x2) | |
EPS Output (with battery) | Peak apparent AC power [kVA] | 66 |
Nominal voltage [V]; Frequency [Hz] | 3P4W, 400/230V, 380/220V; 50/60HZ | |
Max. output continuous current [A] | 100.3 | |
Switch time [ms] | < 10 | |
General | Max. efficiency [%] | 98 |
European weighted efficiency [%] | 97.2 | |
Ingress protection | IP66 | |
Operating ambient temperature range [°C] | - 35 ~ 60 | |
Max. operating altitude [m] | < 3000 | |
Relative humidity [%] | 0 ~ 100 | |
Typical noise emission [dB] | < 70 | |
Dimensions (W×H×D) [mm] | 820 × 670 × 257 | |
Net weight [kg] | < 105 | |
Cooling concept | Smart air cooling | |
Communication interfaces | RS485, CAN(BMS), CAN, USB, DI, DO, DRM | |
Display | LCD (optional) | |
Power Consumption | Standby consumption (night) [W] | < 10 |
Protection | Over/under voltage protection | Yes |
DC isolation protection | Yes | |
DC reverse-polarity protection | Yes | |
Grid monitoring | Yes | |
DC injection monitoring | Yes | |
Back feed current monitoring | Yes | |
Residual current detection | Yes | |
Anti-islanding protection | Yes | |
Over temperature protection | Yes | |
SPD (DC/AC) | Type II/Type II | |
Arc-fault circuit interrupter (AFCI) | Optional | |
Standard | Safety | EN/IEC 62109-1/-2 |
EMC | EN 61000-6-1/2/3/ 4, EN 61000-3-11/12, EN 55011, IEC 62920 | |
Cetification | VDE4105, G99, AS4777, EN50549, CEI 0-21, IEC61727, PEA/MEA, NRS-097-2-1, RD1699, TOR |