HS50E-D
Lightweight, compact, and easy to set up
Available in wall-mounted or floor-mounted options
Fit a wide range of SolaX single and three-phase inverters
Max. 50A charge/discharge current
-30°C to 53°C operational range with advanced heating technology
Higher SOC/SOH accuracy through AI battery model algorithms
Automotive-grade cell sampling chips for superior stability and safety
Certified IP66 for outstanding protection
Cobalt-free LFP battery: safe, long-lasting, efficient, high energy density
A robust cycle life of over 6,000 times, ensuring longevity and reliability
Modular design, flexible expansion
Start with 5.12kWh, expand up to 92.16kWh
AI-driven real-time monitoring and battery fault diagnosis
Continuous OTA one-click upgrade
SolaX HS50E-D offers high performance with 50A charge/discharge, IP66-certified safety, and over 6,000 cycles for durability. It’s modular, expanding from 5.12kWh to 92.16kWh, and easy to install. AI-driven smart management with OTA upgrades ensures efficient, real-time monitoring and fault diagnosis.
Technical Specification | T-BAT HS 5 |
Nominal capacity [kWh] | 5.1 |
Usable energy 90% DOD [kWh] | 4.6 |
Nominal voltage [V] | 102.4 |
Operating voltage [V] | 90-116 |
Recommend charge/discharge current (A) | 30 |
Max. charge/discharge current (A) | 50 |
Standard power [kW] | 3 |
Max. power [kW] | 5.1 |
Depth of discharge | 90% |
Communication interface | RS485, CAN |
Dimensions (L x W x H) [mm] | 730*150*558 |
Technical Specification | T-BAT HS 10 |
Nominal capacity [kWh] | 10.2 |
Usable energy 90% DOD [kWh] | 9.2 |
Nominal voltage [V] | 204.8 |
Operating voltage [V] | 180-232 |
Recommend charge/discharge current (A) | 30 |
Max. charge/discharge current (A) | 50 |
Standard power [kW] | 6.1 |
Max. power [kW] | 10.2 |
Depth of discharge | 90% |
Communication interface | RS485, CAN |
Dimensions (L x W x H) [mm] | 730*150*876 |
Technical Specification | T-BAT HS 15 |
Nominal capacity [kWh] | 15.3 |
Usable energy 90% DOD [kWh] | 13.8 |
Nominal voltage [V] | 307.2 |
Operating voltage [V] | 270-348 |
Recommend charge/discharge current (A) | 30 |
Max. charge/discharge current (A) | 50 |
Standard power [kW] | 9.2 |
Max. power [kW] | 15.3 |
Depth of discharge | 90% |
Communication interface | RS485, CAN |
Dimensions (L x W x H) [mm] | 730*150*1194 |
Technical Specification | T-BAT HS 20 |
Nominal capacity [kWh] | 20.4 |
Usable energy 90% DOD [kWh] | 18.4 |
Nominal voltage [V] | 409.6 |
Operating voltage [V] | 360-464 |
Recommend charge/discharge current (A) | 30 |
Max. charge/discharge current (A) | 50 |
Standard power [kW] | 12.2 |
Max. power [kW] | 20.4 |
Depth of discharge | 90% |
Communication interface | RS485, CAN |
Dimensions (L x W x H) [mm] | 730*150*1194 |
Technical Specification | T-BAT HS 25 |
Nominal capacity [kWh] | 25.6 |
Usable energy 90% DOD [kWh] | 23 |
Nominal voltage [V] | 512 |
Operating voltage [V] | 450-580 |
Recommend charge/discharge current (A) | 30 |
Max. charge/discharge current (A) | 50 |
Standard power [kW] | 15.3 |
Max. power [kW] | 25.6 |
Depth of discharge | 90% |
Communication interface | RS485, CAN |
Dimensions (L x W x H) [mm] | 730*150*1194 |
Technical Specification | T-BAT HS 30 |
Nominal capacity [kWh] | 30.7 |
Usable energy 90% DOD [kWh] | 27.6 |
Nominal voltage [V] | 614.4 |
Operating voltage [V] | 540-696 |
Recommend charge/discharge current (A) | 30 |
Max. charge/discharge current (A) | 50 |
Standard power [kW] | 18.4 |
Max. power [kW] | 30.7 |
Depth of discharge | 90% |
Communication interface | RS485, CAN |
Dimensions (L x W x H) [mm] | 730*150*1194 |