X1-HAC-4 / X1-HAC-7 / X3-HAC-11 / X3-HAC-22

4.6 kW / 7.2 kW / 11 kW / 22 kW

Flexible Adaptability


  • Selectable plug or socket outlet

  • Easy indoor and outdoor installation

  • Supports multiple communication protocols

High Efficiency


  • Capable of 100% green energy

  • Automatic switch between one and three phases

  • Maximizing surplus green energy utilization in a  zero-export system

Assured Safety


  • Current leakage protection (30mA AC & 6mA DC)

  • Smart dynamic load balance control





Intelligent Design


  • Smart RFID management function

  • Smart APP remote control


Why Smart EV Charger G2

SolaX Smart EV Charger G2 is leading the charge in revolutionizing the electric vehicle (EV) charging landscape, offering cutting-edge solutions to meet the surging demand for sustainable transportation. With its advanced features and robust performance, SolaX Smart EV Charger G2 is paving the way for a cleaner and greener future.


X1-HAC-4
X1-HAC-7
X3-HAC-11
X3-HAC-22
CatalogSpecificationX1-HAC-4
AC   Nominal InputVoltage [V]230
Frequency [Hz]50/60
Grid Earth TypeTN, TT, IT
AC   Nominal OutputVoltage [V]230
Current [A]6-20 (single phase)
Power [kW]1.4-4.6
Interface & CommunicationCommunication interfaceWifi/Ethernet/4G (Optional)/RS 485*2
ProtocolOCPP 1.6j, Modbus TCP, Modbus RTU, Cloud API
CommunicateIEC 61851-1, ISO 15118 (Optional)
AuthenticationPlug&Charge/RFID (ISO-14443-A)/APP
MID meterExternal(Optional)
HMIRGB LED / APP / LCD(Optional)
Remote controlAPP&Web
ApplicationResidential/Destination place/Public
General DataHousing materialPC
Installation methodWall/Pedestal(Optional)
Charging outletType2 Plug/Type2 Socket (IEC 62196)
Cable length(m)6.5m(Type P)
Operating Temperature(°C)-30~50
Storage Temperature(°C)-40~60
Working humidity(%)5%~95% without condensation
Working altitude(m)2000m
Degree of ProtectionIP65 (For plug type) / IP54 (For socket type) / K10 (Housing) / IK08(Screen)
Cooling methodNature cooling
Application siteIndoor/Outdoor
Weight [kg]5kg for Plug Type
Dimension(WxHxD) [mm]390x206x139mm
Security ProtectionMultiple ProtectionOver/Under voltage protection, Overload protection, Shortcircuit   protection, Current leakage protection, Grounding protection, Surge protection,   Overtemperature protection
Integral Earth Leakage   ProtectionIntegrated current failure monitoring (30mA AC & 6mA DC)
Cable protectionCable Lock (APP control)
Relay protectionRelay weld detection
Built-in PEN fault technologyAccording to BS 7671:2018 requirements*
StandardIEC 61851-1:2017, IEC 62196-2:2016


CatalogSpecificationX1-HAC-7
AC   Nominal InputVoltage [V]230
Frequency [Hz]50/60
Grid Earth TypeTN, TT, IT
AC   Nominal OutputVoltage [V]230
Current [A]6-32 (single phase)
Power [kW]1.4-7.2
Interface & CommunicationCommunication interfaceWifi/Ethernet/4G (Optional)/RS 485*2
ProtocolOCPP 1.6j, Modbus TCP, Modbus RTU, Cloud API
CommunicateIEC 61851-1, ISO 15118 (Optional)
AuthenticationPlug&Charge/RFID (ISO-14443-A)/APP
MID meterExternal(Optional)
HMIRGB LED / APP / LCD(Optional)
Remote controlAPP&Web
ApplicationResidential/Destination place/Public
General DataHousing materialPC
Installation methodWall/Pedestal(Optional)
Charging outletType2 Plug/Type2 Socket (IEC 62196)
Cable length(m)6.5(Type P)
Operating Temperature(°C)-30~50
Storage Temperature(°C)-40~60
Working humidity(%)5%~95% without condensation
Working altitude(m)2000
Degree of ProtectionIP65 (For plug type)/IP54 (For socket type)   IK10 (Housing) /  IK08(Screen)
Cooling methodNature cooling
Application siteIndoor/Outdoor
Weight [kg]3 for Socket Type
5 for Plug Type
Dimension(WxHxD) [mm]390x206x139
Security ProtectionMultiple ProtectionOver/Under voltage protection,Overload protection,Shortcircuit   protection, Current leakage protection,Grounding protection,Surge protection,   Overtemperature protection
Integral Earth Leakage   ProtectionIntegrated current failure monitoring (30mA AC & 6mA DC)
Cable protectionCable Lock (APP control)
Relay protectionRelay weld detection
Built-in PEN fault technologyAccording to BS 7671:2018 requirements*
StandardIEC 61851-1:2017, IEC 62196-2:2016


CatalogSpecificationX3-HAC-11
AC   Nominal InputVoltage [V]400
Frequency [Hz]50/60
Grid Earth TypeTN,TT,IT
AC   Nominal OutputVoltage [V]400
Current [A]6-16 (single phase)
Power [kW]1.4-11
Interface & CommunicationCommunication interfaceWifi/Ethernet/4G (Optional)/RS 485*2
ProtocolOCPP 1.6j, Modbus TCP, Modbus RTU, Cloud API
CommunicateIEC 61851-1, ISO 15118 (Optional)
AuthenticationPlug&Charge/RFID (ISO-14443-A)/APP
MID meterExternal(Optional)
HMIRGB LED / APP / LCD(Optional)
Remote controlAPP&Web
ApplicationResidential/Destination place/Public
General DataHousing materialPC
Installation methodWall/Pedestal(Optional)
Charging outletType2 Plug/Type2 Socket (IEC 62196)
Cable length(m)6.5(Type P)
Operating Temperature(°C)-30~50
Storage Temperature(°C)-40~60
Working humidity(%)5%~95% without condensation
Working altitude(m)2000
Degree of ProtectionIP65 (For plug type)/IP54 (For socket type)  IK10 (Housing) / IK08(Screen)
Cooling methodNature cooling
Application siteIndoor/Outdoor
Weight [kg]3 for Socket Type
6.5 for Plug Type
Dimension(WxHxD) [mm]390x206x139
Security ProtectionMultiple ProtectionOver/Under voltage protection,Overload protection,Shortcircuit   protection, Current leakage protection,Grounding protection,Surge protection,   Overtemperature protection
Integral Earth Leakage   ProtectionIntegrated current failure monitoring (30mA AC & 6mA DC)
Cable protectionCable Lock (APP control)
Relay protectionRelay weld detection
Built-in PEN fault technologyAccording to BS 7671:2018 requirements*
StandardIEC 61851-1:2017, IEC 62196-2:2016



CatalogSpecificationX3-HAC-22
AC   Nominal InputVoltage [V]400
Frequency [Hz]50/60
Grid Earth TypeTN,TT,IT
AC   Nominal OutputVoltage [V]400
Current [A]6-32 (single phase)
Power [kW]1.4-22
Interface & CommunicationCommunication interfaceWifi/Ethernet/4G (Optional)/RS 485*2
ProtocolOCPP 1.6j, Modbus TCP, Modbus RTU, Cloud API
CommunicateIEC 61851-1, ISO 15118 (Optional)
AuthenticationPlug&Charge/RFID (ISO-14443-A)/APP
MID meterExternal(Optional)
HMIRGB LED / APP / LCD(Optional)
Remote controlAPP&Web
ApplicationResidential/Destination place/Public
General DataHousing materialPC
Installation methodWall/Pedestal(Optional)
Charging outletType2 Plug/Type2 Socket (IEC 62196)
Cable length(m)6.5(Type P)
Operating Temperature(°C)-30~50
Storage Temperature(°C)-40~60
Working humidity(%)5%~95% without condensation
Working altitude(m)2000
Degree of ProtectionIP65 (For plug type)/IP54 (For socket type)  IK10 (Housing) / IK08(Screen)
Cooling methodNature cooling
Application siteIndoor/Outdoor
Weight [kg]3 for Socket Type
6.5 for Plug Typ
Dimension(WxHxD) [mm]390x206x139
Security ProtectionMultiple ProtectionOver/Under voltage protection,Overload protection,Shortcircuit   protection, Current leakage protection,Grounding protection,Surge protection,   Overtemperature protection
Integral Earth Leakage   ProtectionIntegrated current failure monitoring (30mA AC & 6mA DC)
Cable protectionCable Lock (APP control)
Relay protectionRelay weld detection
Built-in PEN fault technologyAccording to BS 7671:2018 requirements*
StandardIEC 61851-1:2017, IEC 62196-2:2016



Related Products
Documents
Datasheet
Language
English
Format
PDF
Size
341.18 KB
Last updated
20/11/2024
User Manual
Language
English
Format
PDF
Size
15.0 MB
Last updated
12/10/2024
Language
Nederlands
Format
PDF
Size
14.3MB
Last updated
27/09/2024
Installation Guide
Language
Global
Format
PDF
Size
11.9M
Last updated
12/10/2024
Language
English
Format
PDF
Size
10.9MB
Last updated
12/10/2024
Feedback
Info
Role
Installer
Distributor
End User
Others
Further information can be found in the privacy policy. I understand that I can withdraw my consent at any time.
I agree with SolaX data protection directive
SolaX Power Network Technology (Zhejiang) Co.,Ltd.
We use cookies to optimise and personalise your experience, but you can choose to opt out of non-essential cookies.
To find out more, read our Privacy Policy and Terms of Use
Reject All
Accept All
Leave Your Message