X1-HAC-4 / X1-HAC-7 / X3-HAC-11 / X3-HAC-22
4.6 kW / 7.2 kW / 11 kW / 22 kW
Selectable plug or socket outlet
Easy indoor and outdoor installation
Supports multiple communication protocols
Capable of 100% green energy
Automatic switch between one and three phases
Maximizing surplus green energy utilization in a zero-export system
Current leakage protection (30mA AC & 6mA DC)
Smart dynamic load balance control
Smart RFID management function
Smart APP remote control
SolaX Smart EV Charger G2 is leading the charge in revolutionizing the electric vehicle (EV) charging landscape, offering cutting-edge solutions to meet the surging demand for sustainable transportation. With its advanced features and robust performance, SolaX Smart EV Charger G2 is paving the way for a cleaner and greener future.
Catalog | Specification | X1-HAC-4 |
AC Nominal Input | Voltage [V] | 230 |
Frequency [Hz] | 50/60 | |
Grid Earth Type | TN, TT, IT | |
AC Nominal Output | Voltage [V] | 230 |
Current [A] | 6-20 (single phase) | |
Power [kW] | 1.4-4.6 | |
Interface & Communication | Communication interface | Wifi/Ethernet/4G (Optional)/RS 485*2 |
Protocol | OCPP 1.6j, Modbus TCP, Modbus RTU, Cloud API | |
Communicate | IEC 61851-1, ISO 15118 (Optional) | |
Authentication | Plug&Charge/RFID (ISO-14443-A)/APP | |
MID meter | External(Optional) | |
HMI | RGB LED / APP / LCD(Optional) | |
Remote control | APP&Web | |
Application | Residential/Destination place/Public | |
General Data | Housing material | PC |
Installation method | Wall/Pedestal(Optional) | |
Charging outlet | Type2 Plug/Type2 Socket (IEC 62196) | |
Cable length(m) | 6.5m(Type P) | |
Operating Temperature(°C) | -30~50 | |
Storage Temperature(°C) | -40~60 | |
Working humidity(%) | 5%~95% without condensation | |
Working altitude(m) | 2000m | |
Degree of Protection | IP65 (For plug type) / IP54 (For socket type) / K10 (Housing) / IK08(Screen) | |
Cooling method | Nature cooling | |
Application site | Indoor/Outdoor | |
Weight [kg] | 5kg for Plug Type | |
Dimension(WxHxD) [mm] | 390x206x139mm | |
Security Protection | Multiple Protection | Over/Under voltage protection, Overload protection, Shortcircuit protection, Current leakage protection, Grounding protection, Surge protection, Overtemperature protection |
Integral Earth Leakage Protection | Integrated current failure monitoring (30mA AC & 6mA DC) | |
Cable protection | Cable Lock (APP control) | |
Relay protection | Relay weld detection | |
Built-in PEN fault technology | According to BS 7671:2018 requirements* | |
Standard | IEC 61851-1:2017, IEC 62196-2:2016 |
Catalog | Specification | X1-HAC-7 |
AC Nominal Input | Voltage [V] | 230 |
Frequency [Hz] | 50/60 | |
Grid Earth Type | TN, TT, IT | |
AC Nominal Output | Voltage [V] | 230 |
Current [A] | 6-32 (single phase) | |
Power [kW] | 1.4-7.2 | |
Interface & Communication | Communication interface | Wifi/Ethernet/4G (Optional)/RS 485*2 |
Protocol | OCPP 1.6j, Modbus TCP, Modbus RTU, Cloud API | |
Communicate | IEC 61851-1, ISO 15118 (Optional) | |
Authentication | Plug&Charge/RFID (ISO-14443-A)/APP | |
MID meter | External(Optional) | |
HMI | RGB LED / APP / LCD(Optional) | |
Remote control | APP&Web | |
Application | Residential/Destination place/Public | |
General Data | Housing material | PC |
Installation method | Wall/Pedestal(Optional) | |
Charging outlet | Type2 Plug/Type2 Socket (IEC 62196) | |
Cable length(m) | 6.5(Type P) | |
Operating Temperature(°C) | -30~50 | |
Storage Temperature(°C) | -40~60 | |
Working humidity(%) | 5%~95% without condensation | |
Working altitude(m) | 2000 | |
Degree of Protection | IP65 (For plug type)/IP54 (For socket type) IK10 (Housing) / IK08(Screen) | |
Cooling method | Nature cooling | |
Application site | Indoor/Outdoor | |
Weight [kg] | 3 for Socket Type 5 for Plug Type | |
Dimension(WxHxD) [mm] | 390x206x139 | |
Security Protection | Multiple Protection | Over/Under voltage protection,Overload protection,Shortcircuit protection, Current leakage protection,Grounding protection,Surge protection, Overtemperature protection |
Integral Earth Leakage Protection | Integrated current failure monitoring (30mA AC & 6mA DC) | |
Cable protection | Cable Lock (APP control) | |
Relay protection | Relay weld detection | |
Built-in PEN fault technology | According to BS 7671:2018 requirements* | |
Standard | IEC 61851-1:2017, IEC 62196-2:2016 |
Catalog | Specification | X3-HAC-11 |
AC Nominal Input | Voltage [V] | 400 |
Frequency [Hz] | 50/60 | |
Grid Earth Type | TN,TT,IT | |
AC Nominal Output | Voltage [V] | 400 |
Current [A] | 6-16 (single phase) | |
Power [kW] | 1.4-11 | |
Interface & Communication | Communication interface | Wifi/Ethernet/4G (Optional)/RS 485*2 |
Protocol | OCPP 1.6j, Modbus TCP, Modbus RTU, Cloud API | |
Communicate | IEC 61851-1, ISO 15118 (Optional) | |
Authentication | Plug&Charge/RFID (ISO-14443-A)/APP | |
MID meter | External(Optional) | |
HMI | RGB LED / APP / LCD(Optional) | |
Remote control | APP&Web | |
Application | Residential/Destination place/Public | |
General Data | Housing material | PC |
Installation method | Wall/Pedestal(Optional) | |
Charging outlet | Type2 Plug/Type2 Socket (IEC 62196) | |
Cable length(m) | 6.5(Type P) | |
Operating Temperature(°C) | -30~50 | |
Storage Temperature(°C) | -40~60 | |
Working humidity(%) | 5%~95% without condensation | |
Working altitude(m) | 2000 | |
Degree of Protection | IP65 (For plug type)/IP54 (For socket type) IK10 (Housing) / IK08(Screen) | |
Cooling method | Nature cooling | |
Application site | Indoor/Outdoor | |
Weight [kg] | 3 for Socket Type 6.5 for Plug Type | |
Dimension(WxHxD) [mm] | 390x206x139 | |
Security Protection | Multiple Protection | Over/Under voltage protection,Overload protection,Shortcircuit protection, Current leakage protection,Grounding protection,Surge protection, Overtemperature protection |
Integral Earth Leakage Protection | Integrated current failure monitoring (30mA AC & 6mA DC) | |
Cable protection | Cable Lock (APP control) | |
Relay protection | Relay weld detection | |
Built-in PEN fault technology | According to BS 7671:2018 requirements* | |
Standard | IEC 61851-1:2017, IEC 62196-2:2016 |
Catalog | Specification | X3-HAC-22 |
AC Nominal Input | Voltage [V] | 400 |
Frequency [Hz] | 50/60 | |
Grid Earth Type | TN,TT,IT | |
AC Nominal Output | Voltage [V] | 400 |
Current [A] | 6-32 (single phase) | |
Power [kW] | 1.4-22 | |
Interface & Communication | Communication interface | Wifi/Ethernet/4G (Optional)/RS 485*2 |
Protocol | OCPP 1.6j, Modbus TCP, Modbus RTU, Cloud API | |
Communicate | IEC 61851-1, ISO 15118 (Optional) | |
Authentication | Plug&Charge/RFID (ISO-14443-A)/APP | |
MID meter | External(Optional) | |
HMI | RGB LED / APP / LCD(Optional) | |
Remote control | APP&Web | |
Application | Residential/Destination place/Public | |
General Data | Housing material | PC |
Installation method | Wall/Pedestal(Optional) | |
Charging outlet | Type2 Plug/Type2 Socket (IEC 62196) | |
Cable length(m) | 6.5(Type P) | |
Operating Temperature(°C) | -30~50 | |
Storage Temperature(°C) | -40~60 | |
Working humidity(%) | 5%~95% without condensation | |
Working altitude(m) | 2000 | |
Degree of Protection | IP65 (For plug type)/IP54 (For socket type) IK10 (Housing) / IK08(Screen) | |
Cooling method | Nature cooling | |
Application site | Indoor/Outdoor | |
Weight [kg] | 3 for Socket Type 6.5 for Plug Typ | |
Dimension(WxHxD) [mm] | 390x206x139 | |
Security Protection | Multiple Protection | Over/Under voltage protection,Overload protection,Shortcircuit protection, Current leakage protection,Grounding protection,Surge protection, Overtemperature protection |
Integral Earth Leakage Protection | Integrated current failure monitoring (30mA AC & 6mA DC) | |
Cable protection | Cable Lock (APP control) | |
Relay protection | Relay weld detection | |
Built-in PEN fault technology | According to BS 7671:2018 requirements* | |
Standard | IEC 61851-1:2017, IEC 62196-2:2016 |