SolaX Power Network Technology (Zhejiang) Co.,Ltd.
SolaX Power Network Technology (Zhejiang) Co.,Ltd.
ENGLISH(GLOBAL)
battery system t bat sys lv r25 36 1
battery system t bat sys lv r25 36 2
battery system t bat sys lv r25 36 3
battery system t bat sys lv r25 36 1
battery system t bat sys lv r25 36 2
battery system t bat sys lv r25 36 3
Battery

T-BAT-SYS-HV-S2.5/3.6
T-BAT-SYS-HV-S2.5/3.6

S2.5
S3.6

T-BAT HS5.0 / T-BAT HS7.5 / T-BAT HS10.0

T-BAT HS12.5 / T-BAT HS15.0 / T-BAT HS17.5

T-BAT HS20.0 / T-BAT HS22.5 / T-BAT HS25.0

T-BAT HS27.5 / T-BAT HS30.0 / T-BAT HS32.5

T-BAT HS7.2 / T-BAT HS10.8 / T-BAT HS14.4

T-BAT HS18.0 / T-BAT HS21.6 / T-BAT HS25.2

T-BAT HS28.8 / T-BAT HS32.4 / T-BAT HS36.0

T-BAT HS39.6 / T-BAT HS43.2 / T-BAT HS46.8

Flexible Adaptability


  • Extendable capacity for lifetime use

  • Stackable modules, plug and play design

Smart Management


  • Remote fault diagnosis, upgrade and maintenance

  • Unique battery heating tech for low-temperature  operation

  • Optional parallel connection using a two-in-one cable for easy capacity expansion and extend battery lifespan

High Performance


  • 5.1-33.2 kWh wide capacity range

  • Max. 50A charging/discharging current

  • Cycle life > 6000 times

Assured Reliability


  • LiFePO4 battery cell & high-performance processors

  • IP65 protection degree

  • Soft start to protect from a sudden surge

Why T-BAT-SYS-HV-S2.5

Experience high-performance with our LFP battery, featuring a maximum 50A charging/discharging rate and IP65 protection. Unique heating technology enables unrestricted charging and discharging even in frigid weather conditions, ensuring continuous operation. Plus, with a long cycle life of over 6000 cycles and a wide capacity range from 5.1kWh to 33.2kWh, our battery is designed to meet your energy needs. Installation is a breeze, with stackable modules and pre-wired cables, making it easy for a single person to set up. You can rely on our battery's soft start protection and the convenience of remote diagnosis and updates via the inverter, providing you with added peace of mind and efficiency.

T-BAT HS5~32.5
T-BAT HS5.0
T-BAT HS7.5
T-BAT HS10.0
T-BAT HS12.5
T-BAT HS15.0
T-BAT HS17.5
T-BAT HS20.0
T-BAT HS22.5
T-BAT HS25.0
T-BAT HS27.5
T-BAT HS30.0
T-BAT HS32.5
Max. charge/discharge current50A
Max. operating altitude3000m
Dimensions (L*W*H)TBMS-MCS0800(BMS): 510*365*157mm
TP-HS2.5(Battery): 510*365*152mm
Series Box: 510*365*152mm
Net weightTBMS-MCS0800(BMS): 10kg
TP-HS2.5(Battery): 28kg
Series Box: 8.8kg


ModelT-BAT HS5.0
Modules2 modules
Nominal Energy (kWh)5.12
Usable Energy (90% DOD) (kWh)4.6
Nominal Voltage (V)102.4
Operating Voltage Range (V)90-116
Recommended Charge/Discharge Current (A)30
Max. Charge/Discharge Current (A)50
Nominal Power (kW)3
Max. Power (kW)5.1
Depth of Discharge (%)90
Communication InterfaceRS485, CAN
Dimension (L x W x H) (mm)510 x 365 x 522



ModelT-BAT HS7.5
Modules3 modules
Nominal Energy (kWh)7.68
Usable Energy (90% DOD) (kWh)6.9
Nominal Voltage (V)153.6
Operating Voltage Range (V)135-174
Recommended Charge/Discharge Current (A)30
Max. Charge/Discharge Current (A)50
Nominal Power (kW)4.6
Max. Power (kW)7.68
Depth of Discharge (%)90
Communication InterfaceRS485, CAN
Dimension (L x W x H) (mm)510 x 365 x 659.5



ModelT-BAT HS10.0
Modules4 modules
Nominal Energy (kWh)10.24
Usable Energy (90% DOD) (kWh)9.2
Nominal Voltage (V)204.8
Operating Voltage Range (V)180-232
Recommended Charge/Discharge Current (A)30
Max. Charge/Discharge Current (A)50
Nominal Power (kW)6.1
Max. Power (kW)10.24
Depth of Discharge (%)90
Communication InterfaceRS485, CAN
Dimension (L x W x H) (mm)510 x 365 x 797



ModelT-BAT HS12.5
Modules5 modules
Nominal Energy (kWh)12.8
Usable Energy (90% DOD) (kWh)11.5
Nominal Voltage (V)256
Operating Voltage Range (V)225-290
Recommended Charge/Discharge Current (A)30
Max. Charge/Discharge Current (A)50
Nominal Power (kW)7.7
Max. Power (kW)12.8
Depth of Discharge (%)90
Communication InterfaceRS485, CAN
Dimension (L x W x H) (mm)510 x 365 x 934.5



ModelT-BAT HS15.0
Modules6 modules
Nominal Energy (kWh)15.36
Usable Energy (90% DOD) (kWh)13.8
Nominal Voltage (V)307.2
Operating Voltage Range (V)270-349
Recommended Charge/Discharge Current (A)30
Max. Charge/Discharge Current (A)50
Nominal Power (kW)9.2
Max. Power (kW)15.36
Depth of Discharge (%)90
Communication InterfaceRS485, CAN
Dimension (L x W x H) (mm)510 x 365 x 1072



ModelT-BAT HS17.5
Modules7 modules
Nominal Energy (kWh)17.92
Usable Energy (90% DOD) (kWh)16.1
Nominal Voltage (V)358.4
Operating Voltage Range (V)315-406
Recommended Charge/Discharge Current (A)30
Max. Charge/Discharge Current (A)50
Nominal Power (kW)10.8
Max. Power (kW)17.92
Depth of Discharge (%)90
Communication InterfaceRS485, CAN
Dimension (L x W x H) (mm)510 x 365 x 1209.5



ModelT-BAT HS20.0
Modules8 modules
Nominal Energy (kWh)20.48
Usable Energy (90% DOD) (kWh)18.4
Nominal Voltage (V)409.6
Operating Voltage Range (V)360-465
Recommended Charge/Discharge Current (A)30
Max. Charge/Discharge Current (A)50
Nominal Power (kW)12.3
Max. Power (kW)20.48
Depth of Discharge (%)90
Communication InterfaceRS485, CAN
Dimension (L x W x H) (mm)510 x 365 x 1347



ModelT-BAT HS22.5
Modules9 modules
Nominal Energy (kWh)23.04
Usable Energy (90% DOD) (kWh)20.7
Nominal Voltage (V)460.8
Operating Voltage Range (V)405-522
Recommended Charge/Discharge Current (A)30
Max. Charge/Discharge Current (A)50
Nominal Power (kW)13.8
Max. Power (kW)23.04
Depth of Discharge (%)90
Communication InterfaceRS485, CAN
Dimension (L x W x H) (mm)510 x 365 x 1484.5



ModelT-BAT HS25.0
Modules10 modules
Nominal Energy (kWh)25.6
Usable Energy (90% DOD) (kWh)23
Nominal Voltage (V)512
Operating Voltage Range (V)450-580
Recommended Charge/Discharge Current (A)30
Max. Charge/Discharge Current (A)50
Nominal Power (kW)15.4
Max. Power (kW)25.60
Depth of Discharge (%)90
Communication InterfaceRS485, CAN
Dimension (L x W x H) (mm)510 x 365 x 934.5+
510 x 365 x 934.5



ModelT-BAT HS27.5
Modules11 modules
Nominal Energy (kWh)28.16
Usable Energy (90% DOD) (kWh)25.3
Nominal Voltage (V)563.2
Operating Voltage Range (V)495-636
Recommended Charge/Discharge Current (A)30
Max. Charge/Discharge Current (A)50
Nominal Power (kW)16.9
Max. Power (kW)28.16
Depth of Discharge (%)90
Communication InterfaceRS485, CAN
Dimension (L x W x H) (mm)510 x 365 x 1072+
510 x 365 x 934.5



ModelT-BAT HS30.0
Modules12 modules
Nominal Energy (kWh)30.72
Usable Energy (90% DOD) (kWh)27.6
Nominal Voltage (V)614.4
Operating Voltage Range (V)540-695
Recommended Charge/Discharge Current (A)30
Max. Charge/Discharge Current (A)50
Nominal Power (kW)18.4
Max. Power (kW)30.72
Depth of Discharge (%)90
Communication InterfaceRS485, CAN
Dimension (L x W x H) (mm)510 x 365 x 1072+
510 x 365 x 1072



ModelT-BAT HS32.5
Modules13 modules
Nominal Energy (kWh)33.28
Usable Energy (90% DOD) (kWh)29.9
Nominal Voltage (V)665.6
Operating Voltage Range (V)585-750
Recommended Charge/Discharge Current (A)30
Max. Charge/Discharge Current (A)50
Nominal Power (kW)20.0
Max. Power (kW)33.28
Depth of Discharge (%)90
Communication InterfaceRS485, CAN
Dimension (L x W x H) (mm)510 x 365 x 1209.5+
510 x 365 x 1072



T-BAT-SYS-HV-S2.5

Flexible Adaptability


  • Extendable capacity for lifetime use

  • Stackable modules, plug and play design

Smart Management


  • Remote fault diagnosis, upgrade and maintenance

  • Unique battery heating tech for low-temperature operation

  • Optional parallel connection using a two-in-one cable for easy capacity expansion and extend battery lifespan

High Performance


  • 7.3-47.9 kWh wide capacity range

  • Max. 50A charging/discharging current

  • Cycle life > 6000 times

Assured Reliability


  • LiFePO4 battery cell & high-performance processors

  • IP65 protection degree

  • Soft start to protect from a sudden surge

Why T-BAT-SYS-HV-S3.6

Experience high-performance with our LFP battery, featuring a maximum 50A charging/discharging rate and IP65 protection. Unique heating technology enables unrestricted charging and discharging even in frigid weather conditions, ensuring continuous operation. Plus, with a long cycle life of over 6000 cycles and a wide capacity range from 7.3kWh to 47.9kWh, our battery is designed to meet your energy needs. Installation is a breeze, with stackable modules and pre-wired cables, making it easy for a single person to set up. You can rely on our battery's soft start protection and the convenience of remote diagnosis and updates via the inverter, providing you with added peace of mind and efficiency.


T-BAT HS7.2~46.8
T-BAT HS7.2
T-BAT HS10.8
T-BAT HS14.4
T-BAT HS18.0
T-BAT HS21.6
T-BAT HS25.2
T-BAT HS28.8
T-BAT HS32.4
T-BAT HS36.0
T-BAT HS39.6
T-BAT HS43.2
T-BAT HS46.8
Protection degreeIP65
Max. operating altitude3000m
Dimensions (L*W*H)TBMS-MCS0800(BMS): 510 × 365 × 157 mm
TP-HS3.6(Battery): 510*365*152mm
Series Box: 510*365*157mm
Net weightTBMS-MCS0800(BMS): 13kg
TP-HS3.6(Battery): 34kg
Series Box: 10kg


ModelT-BAT HS7.2
Technical Specification2 Modules
Nominal Energy (kWh)7.37
Usable Energy (90% DoD, kWh)6.6
Nominal Voltage (V)102.4
Operating Voltage Range (V)90 ~ 116
Nominal Power (kW)3.5
Max Power (kW)5.1
Dimensions (L × W × H, mm)510 × 365 × 522



ModelT-BAT HS10.8
Technical Specification3 Modules
Nominal Energy (kWh)11.06
Usable Energy (90% DoD, kWh)10.0
Nominal Voltage (V)153.6
Operating Voltage Range (V)135 ~ 174
Nominal Power (kW)5.3
Max Power (kW)7.6
Dimensions (L × W × H, mm)510 × 365 × 659.5




ModelT-BAT HS14.4
Technical Specification4 Modules
Nominal Energy (kWh)14.75
Usable Energy (90% DoD, kWh)13.3
Nominal Voltage (V)204.8
Operating Voltage Range (V)180 ~ 232
Nominal Power (kW)7.1
Max Power (kW)10.2
Dimensions (L × W × H, mm)510 × 365 × 797




ModelT-BAT HS18.0
Technical Specification5 Modules
Nominal Energy (kWh)18.43
Usable Energy (90% DoD, kWh)16.6
Nominal Voltage (V)256.0
Operating Voltage Range (V)225 ~ 290
Nominal Power (kW)8.9
Max Power (kW)12.8
Dimensions (L × W × H, mm)510 × 365 × 934.5




ModelT-BAT HS21.6
Technical Specification6 Modules
Nominal Energy (kWh)22.12
Usable Energy (90% DoD, kWh)19.9
Nominal Voltage (V)307.2
Operating Voltage Range (V)270 ~ 349
Nominal Power (kW)10.7
Max Power (kW)15.3
Dimensions (L × W × H, mm)510 × 365 × 1072




ModelT-BAT HS25.2
Technical Specification7 Modules
Nominal Energy (kWh)25.80
Usable Energy (90% DoD, kWh)23.2
Nominal Voltage (V)358.4
Operating Voltage Range (V)315 ~ 406
Nominal Power (kW)12.5
Max Power (kW)17.9
Dimensions (L × W × H, mm)510 × 365 × 1209.5




ModelT-BAT HS28.8
Technical Specification8 Modules
Nominal Energy (kWh)29.49
Usable Energy (90% DoD, kWh)26.5
Nominal Voltage (V)409.6
Operating Voltage Range (V)360 ~ 465
Nominal Power (kW)14.3
Max Power (kW)20.4
Dimensions (L × W × H, mm)510 × 365 × 1347





ModelT-BAT HS32.4
Technical Specification9 Modules
Nominal Energy (kWh)33.18
Usable Energy (90% DoD, kWh)29.9
Nominal Voltage (V)460.8
Operating Voltage Range (V)405 ~ 522
Nominal Power (kW)16.1
Max Power (kW)23.0
Dimensions (L × W × H, mm)510 × 365 × 1484.5





ModelT-BAT HS36.0
Technical Specification10 Modules
Nominal Energy (kWh)36.86
Usable Energy (90% DoD, kWh)33.1
Nominal Voltage (V)512.0
Operating Voltage Range (V)450 ~ 580
Nominal Power (kW)17.9
Max Power (kW)25.6
Dimensions (L × W × H, mm)510 × 365 × 1622






ModelT-BAT HS39.6
Technical Specification11 Modules
Nominal Energy (kWh)40.55
Usable Energy (90% DoD, kWh)36.8
Nominal Voltage (V)563.2
Operating Voltage Range (V)495 ~ 639
Nominal Power (kW)19.6
Max Power (kW)28.1
Dimensions (L × W × H, mm)510 × 365 × 1759.5






ModelT-BAT HS43.2
Technical Specification12 Modules
Nominal Energy (kWh)44.24
Usable Energy (90% DoD, kWh)40.5
Nominal Voltage (V)614.4
Operating Voltage Range (V)540 ~ 695
Nominal Power (kW)21.4
Max Power (kW)30.7
Dimensions (L × W × H, mm)510 × 365 × 1897







ModelT-BAT HS46.8
Technical Specification13 Modules
Nominal Energy (kWh)47.92
Usable Energy (90% DoD, kWh)43.2
Nominal Voltage (V)665.6
Operating Voltage Range (V)585 ~ 750
Nominal Power (kW)23.2
Max Power (kW)33.2
Dimensions (L × W × H, mm)510 × 365 × 2034.5








T-BAT-SYS-HV-S3.6
Related Products
DataHub 1000 DataHub 1000
DataHub 1000
Intelligent Export Control
Pocket Dongle Pocket Dongle
Pocket Dongle
SolaX Cloud Monitoring
Meter Meter
Meter
Smart Monitoring
Documents
Datasheet
Language
English
Format
PDF
Size
921KB
Last updated
20/11/2024
Language
English
Format
PDF
Size
219KB
Last updated
20/11/2024
Language
Spanish
Format
PDF
Size
121KB
Last updated
10/05/2023
Language
Spanish
Format
PDF
Size
134KB
Last updated
10/05/2023
Language
Português
Format
PDF
Size
122KB
Last updated
26/05/2023
Language
Português
Format
PDF
Size
134KB
Last updated
26/05/2023
Language
Polski
Format
PDF
Size
62KB
Last updated
30/05/2023
Language
Japanese
Format
PDF
Size
2.4M
Last updated
11/13/2023
Language
Japanese
Format
PDF
Size
2.01M
Last updated
11/13/2023
Language
Deutsch
Format
PDF
Size
7.25M
Last updated
09/08/2024
Language
Deutsch
Format
PDF
Size
7.25M
Last updated
09/08/2024
Language
Nederlands
Format
PDF
Size
4.42M
Last updated
27/09/2024
Language
Nederlands
Format
PDF
Size
1.41M
Last updated
27/09/2024
User Manual
Language
Nederlands
Format
PDF
Size
7.38MB
Last updated
27/09/2024
Language
English
Format
PDF
Size
6.89MB
Last updated
6/09/2023
Language
English
Format
PDF
Size
11.2MB
Last updated
21/06/2024
Quick Installation Guide
Language
Globe
Format
PDF
Size
19.0MB
Last updated
21/06/2024
Feedback
Info
Role
Installer
Distributor
End User
Others
Further information can be found in the privacy policy. I understand that I can withdraw my consent at any time.
I agree with SolaX data protection directive
SolaX Power Network Technology (Zhejiang) Co.,Ltd.
We use cookies to optimise and personalise your experience, but you can choose to opt out of non-essential cookies.
To find out more, read our Privacy Policy and Terms of Use
Reject All
Accept All
Leave Your Message