Single-Phase EPS Box
Three-Phase EPS Box
Compact size, flexible installation.
Clear terminal labels, quick and easy wiring.
Supports 63A load, ensuring stable operation.
Wide operating temperature, adapts to extreme conditions.
EPS Box integrates two contactors which provide power steering compatible with EPS change-over application. Configured with EPS Box, for users. It is compatible with X hybrid E version. Together with inverter, EPS Box can achieve intelligent switch between on-grid customers need to connect 13 wires to complete the steering circuit. It can connection and off-grid connection. It can simplify the operation simplify the operation and improve security. and improve security
Category | Parameter | Value |
Grid | Max. AC input current (A) | 63 |
Rated AC voltage (V) | 230 | |
Rated AC frequency (Hz) | 50/60 | |
EPS | Max. EPS input current (A) | 17 |
Rated EPS voltage (V) | 230 | |
Rated EPS frequency (Hz) | 50/60 | |
Load | Rated output current (A), on grid mode | 63 |
Rated output current (A), EPS mode | 17 | |
Rated grid voltage (V) | 230 | |
Rated grid frequency (Hz) | 50/60 | |
General Data | Operating Temperature (°C) | -10~+50 |
Switch Time (s) | 0.5 | |
Dimension (mm) | 300x220x170 | |
Weight (kg) | 3 |
Compact design, easy for flexible installation.
Clearly labeled terminals, simplifies wiring process.
1. Supports 3x63A, ensuring high power stability.
2. Wide operating temperature from -20°C to +60°C.
EPS Box integrates two contactors which provide power steering compatible with EPS change-over application. Configured with EPS Box, for users. It is compatible with X hybrid E version. Together with inverter, EPS Box can achieve intelligent switch between on-grid customers need to connect 13 wires to complete the steering circuit. It can connection and off-grid connection. It can simplify the operation simplify the operation and improve security. and improve security
Category | Parameter | Value |
Grid | Max AC input current (A) | 3x63 |
Rated AC voltage (V) | 3/N/PE~400/230 | |
Rated AC frequency (Hz) | 50/60 | |
EPS | Max EPS input current (A) | 3x63 |
Rated EPS voltage (V) | 3/N/PE~400/230 | |
Rated EPS frequency (Hz) | 50/60 | |
Load | Rated output current (A), on grid mode | 3x63 |
Rated output current (A), EPS mode | 3x63 | |
Rated grid voltage (V) | 3/N/PE~400/230 | |
Rated grid frequency (Hz) | 50/60 | |
General Data | Operating Temperature (掳C) | -20~+60 |
Switch Time (s) | 0.5 | |
Dimension (mm) | 300x220x170 | |
Weight (kg) | 4.85 |