4kW / 5kW / 6kW / 8kW
10kW / 12kW / 15kW
Dual independent battery ports and 2-in-1 function for effortless expansion
Additional ports for simplified wiring and installation
Functional and stylish wiring cover
Microgrid and generator modes for versatile operations
Rapid shutdown function compatible
SPD-Ⅱ protection on both DC/AC sides, AFCI optional
10s 200% EPS output with ≤10ms UPS level switch time
V2X ready for smart home energy integration
Intuitive management with Smart Schedule, Scene, and TOU
VPP ready, supporting FCAS, 2030.5, and OpenADR
Wireless meter compatible for convenient setup
20A DC input per MPPT with 3 trackers
200% PV oversizing and 110% AC overloading
Ultra-wide MPPT range of 110-950V
X3-HYB-G4 PRO offers flexible expansion with dual independent battery ports and versatile microgrid and generator modes. It ensures safety with rapid shutdown compatibility, SPD-II protection, and 10s 200% EPS output with fast UPS-level switch time. Smart energy management is enabled with V2X readiness, intuitive controls, and VPP compatibility. Economically, it supports 200% PV oversizing, 110% AC overloading, and features a 20A DC input per MPPT with 3 trackers, all within an ultra-wide MPPT range of 110-950V.
Parameter | X3-HYB-4.0-P |
Max. recommended PV array power [Wp] | 8000 |
Max. input voltage [V] | 1000 |
Nominal DC operating voltage [V] | 650 |
No. of MPP trackers / Strings per MPP tracker | 2 (1 / 1) |
Max. input current (input 1 / input 2 / input 3) [A] | PV1:20 / PV2:20 |
Max. short circuit current (input 1 / input 2 / input 3) [A] | PV1:25 / PV2:25 |
MPPT operating voltage range [V] | 110-950 |
Start output voltage [V] | 140 |
Nominal AC power [VA] | 4000 |
Max. apparent AC power [VA] | 4400 |
Rated grid voltage (AC voltage range) [V] | 3P4W, 400 / 380 |
Rated grid frequency [Hz] | 50 / 60 |
Nominal AC current [A] (at 230V) | 5.8 |
Max. AC current [A] | 6.7 |
Displacement power factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) |
Total harmonic distortion (THDi, rated power) [%] | <3 |
Nominal AC power [VA] | 8000 |
Nominal AC current [A] | 11.6 |
Max. AC current [A] | 12.2 |
Rated grid voltage (AC voltage range) [V] | 3P4W, 400 / 380 |
Rated grid frequency [Hz] | 50 / 60 |
Parameter | X3-HYB-5.0-P |
Max. recommended PV array power [Wp] | 10000 |
Max. input voltage [V] | 1000 |
Nominal DC operating voltage [V] | 650 |
No. of MPP trackers / Strings per MPP tracker | 2 (1 / 1) |
Max. input current (input 1 / input 2 / input 3) [A] | PV1:20 / PV2:20 |
Max. short circuit current (input 1 / input 2 / input 3) [A] | PV1:25 / PV2:25 |
MPPT operating voltage range [V] | 110-950 |
Start output voltage [V] | 140 |
Nominal AC power [VA] | 5000(AS 4777 4999) |
Max. apparent AC power [VA] | 5500(AS 4777 4999) |
Rated grid voltage (AC voltage range) [V] | 3P4W, 400 / 380 |
Rated grid frequency [Hz] | 50 / 60 |
Nominal AC current [A] (at 230V) | 7.2 |
Max. AC current [A] | 8.4 |
Displacement power factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) |
Total harmonic distortion (THDi, rated power) [%] | <3 |
Nominal AC power [VA] | 10000 |
Nominal AC current [A] | 14.5 |
Max. AC current [A] | 15.2 |
Rated grid voltage (AC voltage range) [V] | 3P4W, 400 / 380 |
Rated grid frequency [Hz] | 50 / 60 |
Parameter | X3-HYB-6.0-P |
Max. recommended PV array power [Wp] | 12000 |
Max. input voltage [V] | 1000 |
Nominal DC operating voltage [V] | 650 |
No. of MPP trackers / Strings per MPP tracker | 2 (1 / 1) |
Max. input current (input 1 / input 2 / input 3) [A] | PV1:20 / PV2:20 |
Max. short circuit current (input 1 / input 2 / input 3) [A] | PV1:25 / PV2:25 |
MPPT operating voltage range [V] | 110-950 |
Start output voltage [V] | 140 |
Nominal AC power [VA] | 6000 |
Max. apparent AC power [VA] | 6600 |
Rated grid voltage (AC voltage range) [V] | 3P4W, 400 / 380 |
Rated grid frequency [Hz] | 50 / 60 |
Nominal AC current [A] (at 230V) | 8.7 |
Max. AC current [A] | 10 |
Displacement power factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) |
Total harmonic distortion (THDi, rated power) [%] | <3 |
Nominal AC power [VA] | 12000 |
Nominal AC current [A] | 17.4 |
Max. AC current [A] | 18.2 |
Rated grid voltage (AC voltage range) [V] | 3P4W, 400 / 380 |
Rated grid frequency [Hz] | 50 / 60 |
Parameter | X3-HYB-8.0-P |
Max. recommended PV array power [Wp] | 16000 |
Max. input voltage [V] | 1000 |
Nominal DC operating voltage [V] | 650 |
No. of MPP trackers / Strings per MPP tracker | 3 (1 / 1 / 1) |
Max. input current (input 1 / input 2 / input 3) [A] | PV1:20 / PV2:20 / PV3:20 |
Max. short circuit current (input 1 / input 2 / input 3) [A] | PV1:25 / PV2:25 / PV3:25 |
MPPT operating voltage range [V] | 110-950 |
Start output voltage [V] | 140 |
Nominal AC power [VA] | 8000 |
Max. apparent AC power [VA] | 8800 |
Rated grid voltage (AC voltage range) [V] | 3P4W, 400 / 380 |
Rated grid frequency [Hz] | 50 / 60 |
Nominal AC current [A] (at 230V) | 11.6 |
Max. AC current [A] | 13.4 |
Displacement power factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) |
Total harmonic distortion (THDi, rated power) [%] | <3 |
Nominal AC power [VA] | 16000 |
Nominal AC current [A] | 23.2 |
Max. AC current [A] | 24.3 |
Rated grid voltage (AC voltage range) [V] | 3P4W, 400 / 380 |
Rated grid frequency [Hz] | 50 / 60 |
Parameter | X3-HYB-10.0-P |
Max. recommended PV array power [Wp] | 20000 |
Max. input voltage [V] | 1000 |
Nominal DC operating voltage [V] | 650 |
No. of MPP trackers / Strings per MPP tracker | 3 (1 / 1 / 1) |
Max. input current (input 1 / input 2 / input 3) [A] | PV1:20 / PV2:20 / PV3:20 |
Max. short circuit current (input 1 / input 2 / input 3) [A] | PV1:25 / PV2:25 / PV3:25 |
MPPT operating voltage range [V] | 110-950 |
Start output voltage [V] | 140 |
Nominal AC power [VA] | 10000(AS 4777 9999) |
Max. apparent AC power [VA] | 11000(AS 4777 9999) |
Rated grid voltage (AC voltage range) [V] | 3P4W, 400 / 380 |
Rated grid frequency [Hz] | 50 / 60 |
Nominal AC current [A] (at 230V) | 14.5 |
Max. AC current [A] | 16.7 |
Displacement power factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) |
Total harmonic distortion (THDi, rated power) [%] | <3 |
Nominal AC power [VA] | 20000 |
Nominal AC current [A] | 29 |
Max. AC current [A] | 30.4 |
Rated grid voltage (AC voltage range) [V] | 3P4W, 400 / 380 |
Rated grid frequency [Hz] | 50 / 60 |
Parameter | X3-HYB-12.0-P |
Max. recommended PV array power [Wp] | 24000 |
Max. input voltage [V] | 1000 |
Nominal DC operating voltage [V] | 650 |
No. of MPP trackers / Strings per MPP tracker | 3 (1 / 1 / 1) |
Max. input current (input 1 / input 2 / input 3) [A] | PV1:20 / PV2:20 / PV3:20 |
Max. short circuit current (input 1 / input 2 / input 3) [A] | PV1:25 / PV2:25 / PV3:25 |
MPPT operating voltage range [V] | 110-950 |
Start output voltage [V] | 140 |
Nominal AC power [VA] | 12000 |
Max. apparent AC power [VA] | 13200 |
Rated grid voltage (AC voltage range) [V] | 3P4W, 400 / 380 |
Rated grid frequency [Hz] | 50 / 60 |
Nominal AC current [A] (at 230V) | 17.5 |
Max. AC current [A] | 20 |
Displacement power factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) |
Total harmonic distortion (THDi, rated power) [%] | <3 |
Nominal AC power [VA] | 20000 |
Nominal AC current [A] | 29 |
Max. AC current [A] | 30.4 |
Rated grid voltage (AC voltage range) [V] | 3P4W, 400 / 380 |
Rated grid frequency [Hz] | 50 / 60 |
Parameter | X3-HYB-15.0-P |
Max. recommended PV array power [Wp] | 30000 |
Max. input voltage [V] | 1000 |
Nominal DC operating voltage [V] | 650 |
No. of MPP trackers / Strings per MPP tracker | 3 (1 / 1 / 1) |
Max. input current (input 1 / input 2 / input 3) [A] | PV1:20 / PV2:20 / PV3:20 |
Max. short circuit current (input 1 / input 2 / input 3) [A] | PV1:25 / PV2:25 / PV3:25 |
MPPT operating voltage range [V] | 110-950 |
Start output voltage [V] | 140 |
Nominal AC power [VA] | 15000(AS 4777 14999) |
Max. apparent AC power [VA] | 16500(AS 4777 14999) |
Rated grid voltage (AC voltage range) [V] | 3P4W, 400 / 380 |
Rated grid frequency [Hz] | 50 / 60 |
Nominal AC current [A] (at 230V) | 21.8 |
Max. AC current [A] | 25 |
Displacement power factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) |
Total harmonic distortion (THDi, rated power) [%] | <3 |
Nominal AC power [VA] | 20000 |
Nominal AC current [A] | 29 |
Max. AC current [A] | 30.4 |
Rated grid voltage (AC voltage range) [V] | 3P4W, 400 / 380 |
Rated grid frequency [Hz] | 50 / 60 |