SolaX Power Network Technology (Zhejiang) Co.,Ltd.
SolaX Power Network Technology (Zhejiang) Co.,Ltd.
ENGLISH(GLOBAL)
1
_1722834708
_1722834623
Hybrid Inverter

X3-HYB-G4 PRO
X3-HYB-G4 PRO

X3-HYB-G4 PRO

4kW / 5kW / 6kW / 8kW

10kW / 12kW / 15kW


Flexible Expansion


  • Dual independent battery ports and 2-in-1 function for  effortless expansion

  • Additional ports for simplified wiring and installation

  • Functional and stylish wiring cover

  • Microgrid and generator modes for versatile operations




Safe and Reliable


  • Rapid shutdown function compatible

  • SPD-Ⅱ protection on both DC/AC sides, AFCI optional

  • 10s 200% EPS output with ≤10ms UPS level switch time


Smart Energy


  • V2X ready for smart home energy integration

  • Intuitive management with Smart Schedule, Scene,  and TOU

  • VPP ready, supporting FCAS, 2030.5, and OpenADR

  • Wireless meter compatible for convenient setup




Economically Efficient


  • 20A DC input per MPPT with 3 trackers

  • 200% PV oversizing and 110% AC overloading

  • Ultra-wide MPPT range of 110-950V

Why X3-HYB-G4 PRO

X3-HYB-G4 PRO offers flexible expansion with dual independent battery ports and versatile microgrid and generator modes. It ensures safety with rapid shutdown compatibility, SPD-II protection, and 10s 200% EPS output with fast UPS-level switch time. Smart energy management is enabled with V2X readiness, intuitive controls, and VPP compatibility. Economically, it supports 200% PV oversizing, 110% AC overloading, and features a 20A DC input per MPPT with 3 trackers, all within an ultra-wide MPPT range of 110-950V.

X3-HYB-4.0-P
X3-HYB-5.0-P
X3-HYB-6.0-P
X3-HYB-8.0-P
X3-HYB-10.0-P
X3-HYB-12.0-P
X3-HYB-15.0-P
ParameterX3-HYB-4.0-P
Max. recommended PV array power [Wp]8000
Max. input voltage [V]1000
Nominal DC operating voltage [V]650
No. of MPP trackers / Strings per MPP tracker2 (1 / 1)
Max. input current (input 1 / input 2 / input 3) [A]PV1:20 / PV2:20
Max. short circuit current (input 1 / input 2 / input 3) [A]PV1:25 / PV2:25
MPPT operating voltage range [V]110-950
Start output voltage [V]140
Nominal AC power [VA]4000
Max. apparent AC power [VA]4400
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60
Nominal AC current [A] (at 230V)5.8
Max. AC current [A]6.7
Displacement power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
Total harmonic distortion (THDi, rated power) [%]<3
Nominal AC power [VA]8000
Nominal AC current [A]11.6
Max. AC current [A]12.2
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60


ParameterX3-HYB-5.0-P
Max. recommended PV array power [Wp]10000
Max. input voltage [V]1000
Nominal DC operating voltage [V]650
No. of MPP trackers / Strings per MPP tracker2 (1 / 1)
Max. input current (input 1 / input 2 / input 3) [A]PV1:20 / PV2:20
Max. short circuit current (input 1 / input 2 / input 3) [A]PV1:25 / PV2:25
MPPT operating voltage range [V]110-950
Start output voltage [V]140
Nominal AC power [VA]5000(AS 4777 4999)
Max. apparent AC power [VA]5500(AS 4777 4999)
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60
Nominal AC current [A] (at 230V)7.2
Max. AC current [A]8.4
Displacement power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
Total harmonic distortion (THDi, rated power) [%]<3
Nominal AC power [VA]10000
Nominal AC current [A]14.5
Max. AC current [A]15.2
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60


ParameterX3-HYB-6.0-P
Max. recommended PV array power [Wp]12000
Max. input voltage [V]1000
Nominal DC operating voltage [V]650
No. of MPP trackers / Strings per MPP tracker2 (1 / 1)
Max. input current (input 1 / input 2 / input 3) [A]PV1:20 / PV2:20
Max. short circuit current (input 1 / input 2 / input 3) [A]PV1:25 / PV2:25
MPPT operating voltage range [V]110-950
Start output voltage [V]140
Nominal AC power [VA]6000
Max. apparent AC power [VA]6600
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60
Nominal AC current [A] (at 230V)8.7
Max. AC current [A]10
Displacement power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
Total harmonic distortion (THDi, rated power) [%]<3
Nominal AC power [VA]12000
Nominal AC current [A]17.4
Max. AC current [A]18.2
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60


ParameterX3-HYB-8.0-P
Max. recommended PV array power [Wp]16000
Max. input voltage [V]1000
Nominal DC operating voltage [V]650
No. of MPP trackers / Strings per MPP tracker3 (1 / 1 / 1)
Max. input current (input 1 / input 2 / input 3) [A]PV1:20 / PV2:20 / PV3:20
Max. short circuit current (input 1 / input 2 / input 3) [A]PV1:25 / PV2:25 / PV3:25
MPPT operating voltage range [V]110-950
Start output voltage [V]140
Nominal AC power [VA]8000
Max. apparent AC power [VA]8800
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60
Nominal AC current [A] (at 230V)11.6
Max. AC current [A]13.4
Displacement power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
Total harmonic distortion (THDi, rated power) [%]<3
Nominal AC power [VA]16000
Nominal AC current [A]23.2
Max. AC current [A]24.3
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60


ParameterX3-HYB-10.0-P
Max. recommended PV array power [Wp]20000
Max. input voltage [V]1000
Nominal DC operating voltage [V]650
No. of MPP trackers / Strings per MPP tracker3 (1 / 1 / 1)
Max. input current (input 1 / input 2 / input 3) [A]PV1:20 / PV2:20 / PV3:20
Max. short circuit current (input 1 / input 2 / input 3) [A]PV1:25 / PV2:25 / PV3:25
MPPT operating voltage range [V]110-950
Start output voltage [V]140
Nominal AC power [VA]10000(AS 4777 9999)
Max. apparent AC power [VA]11000(AS 4777 9999)
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60
Nominal AC current [A] (at 230V)14.5
Max. AC current [A]16.7
Displacement power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
Total harmonic distortion (THDi, rated power) [%]<3
Nominal AC power [VA]20000
Nominal AC current [A]29
Max. AC current [A]30.4
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60


ParameterX3-HYB-12.0-P
Max. recommended PV array power [Wp]24000
Max. input voltage [V]1000
Nominal DC operating voltage [V]650
No. of MPP trackers / Strings per MPP tracker3 (1 / 1 / 1)
Max. input current (input 1 / input 2 / input 3) [A]PV1:20 / PV2:20 / PV3:20
Max. short circuit current (input 1 / input 2 / input 3) [A]PV1:25 / PV2:25 / PV3:25
MPPT operating voltage range [V]110-950
Start output voltage [V]140
Nominal AC power [VA]12000
Max. apparent AC power [VA]13200
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60
Nominal AC current [A] (at 230V)17.5
Max. AC current [A]20
Displacement power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
Total harmonic distortion (THDi, rated power) [%]<3
Nominal AC power [VA]20000
Nominal AC current [A]29
Max. AC current [A]30.4
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60


ParameterX3-HYB-15.0-P
Max. recommended PV array power [Wp]30000
Max. input voltage [V]1000
Nominal DC operating voltage [V]650
No. of MPP trackers / Strings per MPP tracker3 (1 / 1 / 1)
Max. input current (input 1 / input 2 / input 3) [A]PV1:20 / PV2:20 / PV3:20
Max. short circuit current (input 1 / input 2 / input 3) [A]PV1:25 / PV2:25 / PV3:25
MPPT operating voltage range [V]110-950
Start output voltage [V]140
Nominal AC power [VA]15000(AS 4777 14999)
Max. apparent AC power [VA]16500(AS 4777 14999)
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60
Nominal AC current [A] (at 230V)21.8
Max. AC current [A]25
Displacement power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
Total harmonic distortion (THDi, rated power) [%]<3
Nominal AC power [VA]20000
Nominal AC current [A]29
Max. AC current [A]30.4
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60


Related Products
DataHub 1000 DataHub 1000
DataHub 1000
Intelligent Export Control
Meter Meter
Meter
Smart Monitoring
Documents
Datasheet
Language
English
Format
PDF
Size
422KB
Last updated
05/08/2024
Feedback
Info
Role
Installer
Distributor
End User
Others
Further information can be found in the privacy policy. I understand that I can withdraw my consent at any time.
I agree with SolaX data protection directive
SolaX Power Network Technology (Zhejiang) Co.,Ltd.
We use cookies to optimise and personalise your experience, but you can choose to opt out of non-essential cookies.
To find out more, read our Privacy Policy and Terms of Use
Reject All
Accept All
Leave Your Message