V2X ready for smart home energy integration
Smart Schedule, Smart Scene, and 7*24h TOU
Wireless meter compatibility
VPP ready with a variety of compatibility(OpenADR, IEEE2030.5, FCAS, API)
Dual battery ports & 2-in-1 function for expansion
Additional ports for simplified wiring and installation
Functional and stylish wiring cover
Microgrid and generator modes for versatile operations
20A DC input per MPPT with 3 trackers
200% PV oversizing and up to 110% AC output
Ultra-wide MPPT range of 110-950V
Up to 200% EPS output for 10s
UPS-level switchover time <10ms
Optional Rapid Shutdown function for enhanced safety
Type II SPD on AC&DC side
Optional AFCI protection*
X3-HYB-G4 PRO offers flexible expansion with dual independent battery ports and versatile microgrid and generator modes. It ensures safety with rapid shutdown compatibility, SPD-II protection, and 10s 200% EPS output with fast UPS-level switch time. Smart energy management is enabled with V2X readiness, intuitive controls, and VPP compatibility. Economically, it supports 200% PV oversizing, 110% AC overloading, and features a 20A DC input per MPPT with 3 trackers, all within an ultra-wide MPPT range of 110-950V.
Parameter | X3-HYB-4.0-P |
Max. recommended PV array power | 8 kWp |
Max. PV input voltage | 1000 V |
Nominal PV input voltage | 650 V |
Operating voltage range | 110 ~ 950 V |
MPPT voltage range | 110 ~ 950 V |
Start-up voltage | 120 V |
No. of MPP trackers / Strings per MPP tracker | 2 (1 / 1) |
Max. input current per MPPT (MPPT1/2/3) | 20 A / 20 A |
Max. input short circuit current per MPPT (MPPT1/2/3) | 25 A / 25 A |
Rated output power | 4000 W |
Rated output current | 5.8 A |
Max. output apparent power | 4400 VA |
Max. output continuous current | 6.7 A |
Nominal AC voltage | 3 / N / PE, 220 / 380 V |
Max. AC input apparent power | 8.4 kVA |
Max. AC input current | 12.2 A |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | <3% |
Parameter | X3-HYB-5.0-P |
Max. recommended PV array power | 10 kWp |
Max. PV input voltage | 1000 V |
Nominal PV input voltage | 650 V |
Operating voltage range | 110 ~ 950 V |
MPPT voltage range | 110 ~ 950 V |
Start-up voltage | 120 V |
No. of MPP trackers / Strings per MPP tracker | 2 (1 / 1) |
Max. input current per MPPT (MPPT1/2/3) | 20 A / 20 A |
Max. input short circuit current per MPPT (MPPT1/2/3) | 25 A / 25 A |
Rated output power | 5000 W |
Rated output current | 7.2 A |
Max. output apparent power | 5500 VA |
Max. output continuous current | 6.7 A |
Nominal AC voltage | 3 / N / PE, 220 / 380 V |
Max. AC input apparent power | 10.5 kVA |
Max. AC input current | 15.2 A |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | <3% |
Parameter | X3-HYB-6.0-P |
Max. recommended PV array power | 12 kWp |
Max. PV input voltage | 1000 V |
Nominal PV input voltage | 650 V |
Operating voltage range | 110 ~ 950 V |
MPPT voltage range | 110 ~ 950 V |
Start-up voltage | 120 V |
No. of MPP trackers / Strings per MPP tracker | 2 (1 / 1) |
Max. input current per MPPT (MPPT1/2/3) | 20 A / 20 A |
Max. input short circuit current per MPPT (MPPT1/2/3) | 25 A / 25 A |
Rated output power | 6000 W |
Rated output current | 8.7 A |
Max. output apparent power | 6600 VA |
Max. output continuous current | 8.4 A |
Nominal AC voltage | 3 / N / PE, 220 / 380 V |
Max. AC input apparent power | 12.6 kVA |
Max. AC input current | 18.2 A |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | <3% |
Parameter | X3-HYB-8.0-P |
Max. recommended PV array power | 16 kWp |
Max. PV input voltage | 1000 V |
Nominal PV input voltage | 650 V |
Operating voltage range | 110 ~ 950 V |
MPPT voltage range | 110 ~ 950 V |
Start-up voltage | 120 V |
No. of MPP trackers / Strings per MPP tracker | 3 (1 / 1 / 1) |
Max. input current per MPPT (MPPT1/2/3) | 20 A / 20 A / 20 A |
Max. input short circuit current per MPPT (MPPT1/2/3) | 25 A / 25 A / 25 A |
Rated output power | 8000 W |
Rated output current | 11.6 A |
Max. output apparent power | 8800 VA |
Max. output continuous current | 10.0 A |
Nominal AC voltage | 3 / N / PE, 220 / 380 V |
Max. AC input apparent power | 16.8 kVA |
Max. AC input current | 24.3 A |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | <3% |
Max. recommended PV array power | 20 kWp |
Max. PV input voltage | 1000 V |
Nominal PV input voltage | 650 V |
Operating voltage range | 110 ~ 950 V |
MPPT voltage range | 110 ~ 950 V |
Start-up voltage | 120 V |
No. of MPP trackers / Strings per MPP tracker | 3 (1 / 1 / 1) |
Max. input current per MPPT (MPPT1/2/3) | 20 A / 20 A / 20 A |
Max. input short circuit current per MPPT (MPPT1/2/3) | 25 A / 25 A / 25 A |
Rated output power | 10000 W |
Rated output current | 14.5 A |
Max. output apparent power | 11000 VA |
Max. output continuous current | 13.4 A |
Nominal AC voltage | 3 / N / PE, 220 / 380 V |
Max. AC input apparent power | 21.0 kVA |
Max. AC input current | 30.4 A |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | <3% |
Parameter | X3-HYB-12.0-P |
Max. recommended PV array power | 24 kWp |
Max. PV input voltage | 1000 V |
Nominal PV input voltage | 650 V |
Operating voltage range | 110 ~ 950 V |
MPPT voltage range | 110 ~ 950 V |
Start-up voltage | 120 V |
No. of MPP trackers / Strings per MPP tracker | 3 (1 / 1 / 1) |
Max. input current per MPPT (MPPT1/2/3) | 20 A / 20 A / 20 A |
Max. input short circuit current per MPPT (MPPT1/2/3) | 25 A / 25 A / 25 A |
Rated output power | 12000 W |
Rated output current | 17.5 A |
Max. output apparent power | 13200 VA |
Max. output continuous current | 20.0 A |
Nominal AC voltage | 3 / N / PE, 230 / 400 V |
Max. AC input apparent power | 24.0 kVA |
Max. AC input current | 35.0 A |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | <3% |
Parameter | X3-HYB-15.0-P |
Max. recommended PV array power | 30 kWp |
Max. PV input voltage | 1000 V |
Nominal PV input voltage | 650 V |
Operating voltage range | 110 ~ 950 V |
MPPT voltage range | 110 ~ 950 V |
Start-up voltage | 120 V |
No. of MPP trackers / Strings per MPP tracker | 3 (1 / 1 / 1) |
Max. input current per MPPT (MPPT1/2/3) | 20 A / 20 A / 20 A |
Max. input short circuit current per MPPT (MPPT1/2/3) | 25 A / 25 A / 25 A |
Rated output power | 15000 W |
Rated output current | 21.8 A |
Max. output apparent power | 16500 VA |
Max. output continuous current | 25.0 A |
Nominal AC voltage | 3 / N / PE, 230 / 400 V |
Max. AC input apparent power | 30.0 kVA |
Max. AC input current | 45.0 A |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~1 (0.8 lagging to 0.8 leading) |
THDi (rated power) | <3% |