8kW / 10kW / 12kW / 15kW
Robust backup ability, switchover time <10ms(UPS level), up to 200% EPS output for 10s, support half-wave loads
Battery heating technology, -30°C extreme environment operation
IP66 protection level
AC&DC SPD type II, always guarding the inverter
AFCI optional
VPP ready, SolaX cloud support resource aggregator(IEEE 2030.5, OpenADR)
Micro-grid ready
Support intelligent loads management①(e.g., Heat pump, EV charger), combined with 7×24h TOU to achieve ecient peak shaving
Support Wireless meter solution
All in one design, plug and play, expandable and installation easily 3MPPT is capable of handling complex multi-faceted roof installations
Maximum 200% oversize,200% PV input power, 20A DC single string input current,
Low start output voltage makes inverter longer working time
Built-in shadow tracking function
Choose X3-IES-P for its robust backup capability, with a swift switchover time of less than 10ms (UPS-level) and an impressive 200% EPS output for 10 seconds, ensuring uninterrupted power supply. Its battery heating technology enables operation in extreme -30°C environments. Safety is paramount, with IP66 protection, AC&DC SPD Type II safeguarding the inverter, and optional AFCI for added protection. Intelligence highlights include VPP readiness, SolaX cloud integration, micro-grid compatibility, and smart load management, optimizing energy usage with 7x24h TOU for efficient peak shaving. Economically, the all-in-one design is plug-and-play, expandable, and easy to install, handling complex multi-faceted roof installations with 3MPPT and a 200% oversize capacity, maximizing PV input power and inverter working time.
X3-IES-8K-P | |
INPUT PV | |
Max. recommended PV array power [Wp] | 16000 |
Max. DC voltage [V] | 1000 |
Nominal DC operating voltage [V] | 600 |
Max. input current (input PV1 / input PV2 / input PV3) [A] | PV1: 20 / PV2: 20 / PV3: 20 |
Start output voltage [V] | 140 |
No. of MPP trackers / Strings per MPP tracker | 3 / (1 / 1 / 1) |
INPUT AC | |
Nominal AC power [VA] | 16000 |
Max. AC current [A] | 25.8 |
Rated grid frequency [Hz] | 50 / 60 |
Power factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) |
OUTPUT AC (On-Grid) | |
Nominal AC power [VA] | 8000 |
Max. apparent AC power [VA] | 8800 |
Rated grid voltage(AC voltage range) [V] | 3P4W, 380 / 400 |
Rated grid frequency [Hz] | 50 / 60 |
Rated AC output current [A] ( at 230V, 50Hz) | 11.6 |
Max. AC current [A] | 12.8 |
Displacement power factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) |
Total harmonic distortion (THDi, rated power) [%] | < 3 |
EPS OUTPUT (With battery) | |
EPS peak power [VA] | ≤1.1Pn continuous operation; 1.1Pn-2Pn 10s; >2Pn report error immediately |
EPS rated power [VA] | 8000 |
EPS rated voltage [V]; frequency [Hz] | 3P4W, 380 / 400, 50 / 60 |
EPS rated current [A] | 11.6 |
Switchover time [ms] | < 10 |
Total harmonic distortion (THDv, linear Load) [%] | < 3 |
Half wave loads [kW] | < 2 |
BATTERY | |
Battery voltage range [V] | 160 ~ 800 |
Communication interfaces | CAN / RS485 |
BMS module | TBMS-MCS0800E |
Battery module | TP-HS50E |
Composition | TBMS-MCS0800E + TP-HS50E * n + Base Dimensions + Series Box(Required for two columns) |
Battery type | Li-ion (LFP) |
Cycle life [Cycles] | > 6000 |
Warranty [Years] | 10 |
Safety | CE, RCM, TUV (IEC62619), RoHS, REACH |
TBMS-MCS0800E dimensions(W × H × D) [mm] / Weight [kg] | 730 × 165 × 150 / 9.3 |
TP-HS50E dimensions(W × H × D) [mm] / Weight [kg] | 730 × 318 × 150 / 47 |
Base dimensions(W × H × D) [mm] / Weight [kg] | 730 × 75 × 150 / 3.9 |
Series box dimensions(W × H × D) [mm] / Weight [kg] | 167 × 91.5 × 121 / 1.3 |
EFFICIENCY | |
Max. efficiency [%] / Euro-efficiency [%] | 98/ 97.7 |
Rated battery charge [%] / Discharge eciency [%] | 98.5 / 97 |
GENERAL DATA (INVERTER) | |
Dimensions (W × H × D) [mm] | 717 × 405 × 209.5 |
Weight [kg] | 40 |
Operating temperature range [°C] | ﹣35 to 60 (derating at +45) |
Relative humidity [%] | 0 to 100 (condensing) |
Storage temperature [°C] | - 40 to 65 |
Noise emission (typical) [dB(A)] | < 33 |
Internal consumption (night) [W] | < 40 for hot standby, < 5 for cold standby |
Idle mode | Yes |
PROTECTION | |
Anti-Islanding protection | Yes |
DC reverse polarity protection | Yes |
Insulation monitoring | Yes |
Residual current monitoring | Yes |
AC overcurrent protection | Yes |
AC short-circuit protection | Yes |
AC overvoltage protection | Yes |
Over-heat protection | Yes |
AFCI | OPT |
Surge protection | Type Ⅱ, DC and AC |
STANDARD | |
Safety | IEC62109-1 / IEC62109-2 |
EMC | EN 61000-6-1 / EN 61000-6-2 / EN 61000-6-3 |
Certification | VDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21 |
X3-IES-10K-P | |
INPUT PV | |
Max. recommended PV array power [Wp] | 20000 |
Max. DC voltage [V] | 1000 |
Nominal DC operating voltage [V] | 600 |
Max. input current (input PV1 / input PV2 / input PV3) [A] | PV1: 20 / PV2: 20 / PV3: 20 |
Start output voltage [V] | 140 |
No. of MPP trackers / Strings per MPP tracker | 3 / (1 / 1 / 1) |
INPUT AC | |
Nominal AC power [VA] | 20000 |
Max. AC current [A] | 32 |
Rated grid frequency [Hz] | 50 / 60 |
Power factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) |
OUTPUT AC (On-Grid) | |
Nominal AC power [VA] | 10000(AS4777 9999) |
Max. apparent AC power [VA] | 10000(AS4777 9999) |
Rated grid voltage(AC voltage range) [V] | 3P4W, 380 / 400 |
Rated grid frequency [Hz] | 50 / 60 |
Rated AC output current [A] ( at 230V, 50Hz) | 14.5 |
Max. AC current [A] | 14.5 |
Displacement power factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) |
Total harmonic distortion (THDi, rated power) [%] | < 3 |
EPS OUTPUT (With battery) | |
EPS peak power [VA] | ≤1.1Pn continuous operation; 1.1Pn-2Pn 10s; >2Pn report error immediately |
EPS rated power [VA] | 10000 |
EPS rated voltage [V]; frequency [Hz] | 3P4W, 380 / 400, 50 / 60 |
EPS rated current [A] | 14.5 |
Switchover time [ms] | < 10 |
Total harmonic distortion (THDv, linear Load) [%] | < 3 |
Half wave loads [kW] | < 2 |
BATTERY | |
Battery voltage range [V] | 160 ~ 800 |
Communication interfaces | CAN / RS485 |
BMS module | TBMS-MCS0800E |
Battery module | TP-HS50E |
Composition | TBMS-MCS0800E + TP-HS50E * n + Base Dimensions + Series Box(Required for two columns) |
Battery type | Li-ion (LFP) |
Cycle life [Cycles] | > 6000 |
Warranty [Years] | 10 |
Safety | CE, RCM, TUV (IEC62619), RoHS, REACH |
TBMS-MCS0800E dimensions(W × H × D) [mm] / Weight [kg] | 730 × 165 × 150 / 9.3 |
TP-HS50E dimensions(W × H × D) [mm] / Weight [kg] | 730 × 318 × 150 / 47 |
Base dimensions(W × H × D) [mm] / Weight [kg] | 730 × 75 × 150 / 3.9 |
Series box dimensions(W × H × D) [mm] / Weight [kg] | 167 × 91.5 × 121 / 1.3 |
EFFICIENCY | |
Max. efficiency [%] / Euro-efficiency [%] | 98/ 97.7 |
Rated battery charge [%] / Discharge eciency [%] | 98.5 / 97 |
GENERAL DATA (INVERTER) | |
Dimensions (W × H × D) [mm] | 717 × 405 × 209.5 |
Weight [kg] | 40 |
Operating temperature range [°C] | ﹣35 to 60 (derating at +45) |
Relative humidity [%] | 0 to 100 (condensing) |
Storage temperature [°C] | - 40 to 65 |
Noise emission (typical) [dB(A)] | < 33 |
Internal consumption (night) [W] | < 40 for hot standby, < 5 for cold standby |
Idle mode | Yes |
PROTECTION | |
Anti-Islanding protection | Yes |
DC reverse polarity protection | Yes |
Insulation monitoring | Yes |
Residual current monitoring | Yes |
AC overcurrent protection | Yes |
AC short-circuit protection | Yes |
AC overvoltage protection | Yes |
Over-heat protection | Yes |
AFCI | OPT |
Surge protection | Type Ⅱ, DC and AC |
STANDARD | |
Safety | IEC62109-1 / IEC62109-2 |
EMC | EN 61000-6-1 / EN 61000-6-2 / EN 61000-6-3 |
Certification | VDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21 |
X3-IES-12K-P | |
INPUT PV | |
Max. recommended PV array power [Wp] | 24000 |
Max. DC voltage [V] | 1000 |
Nominal DC operating voltage [V] | 600 |
Max. input current (input PV1 / input PV2 / input PV3) [A] | PV1: 20 / PV2: 20 / PV3: 20 |
Start output voltage [V] | 140 |
No. of MPP trackers / Strings per MPP tracker | 3 / (1 / 1 / 1) |
INPUT AC | |
Nominal AC power [VA] | 20000 |
Max. AC current [A] | 32 |
Rated grid frequency [Hz] | 50 / 60 |
Power factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) |
OUTPUT AC (On-Grid) | |
Nominal AC power [VA] | 12000 |
Max. apparent AC power [VA] | 13200 |
Rated grid voltage(AC voltage range) [V] | 3P4W, 380 / 400 |
Rated grid frequency [Hz] | 50 / 60 |
Rated AC output current [A] ( at 230V, 50Hz) | 17.4 |
Max. AC current [A] | 19.2 |
Displacement power factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) |
Total harmonic distortion (THDi, rated power) [%] | < 3 |
EPS OUTPUT (With battery) | |
EPS peak power [VA] | ≤1.1Pn continuous operation; 1.1Pn-2Pn 10s; >2Pn report error immediately |
EPS rated power [VA] | 12000 |
EPS rated voltage [V]; frequency [Hz] | 3P4W, 380 / 400, 50 / 60 |
EPS rated current [A] | 17.4 |
Switchover time [ms] | < 10 |
Total harmonic distortion (THDv, linear Load) [%] | < 3 |
Half wave loads [kW] | < 2 |
BATTERY | |
Battery voltage range [V] | 160 ~ 800 |
Communication interfaces | CAN / RS485 |
BMS module | TBMS-MCS0800E |
Battery module | TP-HS50E |
Composition | TBMS-MCS0800E + TP-HS50E * n + Base Dimensions + Series Box(Required for two columns) |
Battery type | Li-ion (LFP) |
Cycle life [Cycles] | > 6000 |
Warranty [Years] | 10 |
Safety | CE, RCM, TUV (IEC62619), RoHS, REACH |
TBMS-MCS0800E dimensions(W × H × D) [mm] / Weight [kg] | 730 × 165 × 150 / 9.3 |
TP-HS50E dimensions(W × H × D) [mm] / Weight [kg] | 730 × 318 × 150 / 47 |
Base dimensions(W × H × D) [mm] / Weight [kg] | 730 × 75 × 150 / 3.9 |
Series box dimensions(W × H × D) [mm] / Weight [kg] | 167 × 91.5 × 121 / 1.3 |
EFFICIENCY | |
Max. efficiency [%] / Euro-efficiency [%] | 98/ 97.7 |
Rated battery charge [%] / Discharge eciency [%] | 98.5 / 97 |
GENERAL DATA (INVERTER) | |
Dimensions (W × H × D) [mm] | 717 × 405 × 209.5 |
Weight [kg] | 40 |
Operating temperature range [°C] | ﹣35 to 60 (derating at +45) |
Relative humidity [%] | 0 to 100 (condensing) |
Storage temperature [°C] | - 40 to 65 |
Noise emission (typical) [dB(A)] | < 33 |
Internal consumption (night) [W] | < 40 for hot standby, < 5 for cold standby |
Idle mode | Yes |
PROTECTION | |
Anti-Islanding protection | Yes |
DC reverse polarity protection | Yes |
Insulation monitoring | Yes |
Residual current monitoring | Yes |
AC overcurrent protection | Yes |
AC short-circuit protection | Yes |
AC overvoltage protection | Yes |
Over-heat protection | Yes |
AFCI | OPT |
Surge protection | Type Ⅱ, DC and AC |
STANDARD | |
Safety | IEC62109-1 / IEC62109-2 |
EMC | EN 61000-6-1 / EN 61000-6-2 / EN 61000-6-3 |
Certification | VDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21 |
X3-IES-15K-P | |
INPUT PV | |
Max. recommended PV array power [Wp] | 30000 |
Max. DC voltage [V] | 1000 |
Nominal DC operating voltage [V] | 600 |
Max. input current (input PV1 / input PV2 / input PV3) [A] | PV1: 20 / PV2: 20 / PV3: 20 |
Start output voltage [V] | 140 |
No. of MPP trackers / Strings per MPP tracker | 3 / (1 / 1 / 1) |
INPUT AC | |
Nominal AC power [VA] | 20000 |
Max. AC current [A] | 32 |
Rated grid frequency [Hz] | 50 / 60 |
Power factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) |
OUTPUT AC (On-Grid) | |
Nominal AC power [VA] | 15000(AS4777 14999) |
Max. apparent AC power [VA] | 165000 |
Rated grid voltage(AC voltage range) [V] | 3P4W, 380 / 400 |
Rated grid frequency [Hz] | 50 / 60 |
Rated AC output current [A] ( at 230V, 50Hz) | 21.8 |
Max. AC current [A] | 24 |
Displacement power factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) |
Total harmonic distortion (THDi, rated power) [%] | < 3 |
EPS OUTPUT (With battery) | |
EPS peak power [VA] | ≤1.1Pn continuous operation; 1.1Pn-2Pn 10s; >2Pn report error immediately |
EPS rated power [VA] | 15000 |
EPS rated voltage [V]; frequency [Hz] | 3P4W, 380 / 400, 50 / 60 |
EPS rated current [A] | 21.8 |
Switchover time [ms] | < 10 |
Total harmonic distortion (THDv, linear Load) [%] | < 3 |
Half wave loads [kW] | < 2 |
BATTERY | |
Battery voltage range [V] | 160 ~ 800 |
Communication interfaces | CAN / RS485 |
BMS module | TBMS-MCS0800E |
Battery module | TP-HS50E |
Composition | TBMS-MCS0800E + TP-HS50E * n + Base Dimensions + Series Box(Required for two columns) |
Battery type | Li-ion (LFP) |
Cycle life [Cycles] | > 6000 |
Warranty [Years] | 10 |
Safety | CE, RCM, TUV (IEC62619), RoHS, REACH |
TBMS-MCS0800E dimensions(W × H × D) [mm] / Weight [kg] | 730 × 165 × 150 / 9.3 |
TP-HS50E dimensions(W × H × D) [mm] / Weight [kg] | 730 × 318 × 150 / 47 |
Base dimensions(W × H × D) [mm] / Weight [kg] | 730 × 75 × 150 / 3.9 |
Series box dimensions(W × H × D) [mm] / Weight [kg] | 167 × 91.5 × 121 / 1.3 |
EFFICIENCY | |
Max. efficiency [%] / Euro-efficiency [%] | 98/ 97.7 |
Rated battery charge [%] / Discharge eciency [%] | 98.5 / 97 |
GENERAL DATA (INVERTER) | |
Dimensions (W × H × D) [mm] | 717 × 405 × 209.5 |
Weight [kg] | 40 |
Operating temperature range [°C] | ﹣35 to 60 (derating at +45) |
Relative humidity [%] | 0 to 100 (condensing) |
Storage temperature [°C] | - 40 to 65 |
Noise emission (typical) [dB(A)] | < 33 |
Internal consumption (night) [W] | < 40 for hot standby, < 5 for cold standby |
Idle mode | Yes |
PROTECTION | |
Anti-Islanding protection | Yes |
DC reverse polarity protection | Yes |
Insulation monitoring | Yes |
Residual current monitoring | Yes |
AC overcurrent protection | Yes |
AC short-circuit protection | Yes |
AC overvoltage protection | Yes |
Over-heat protection | Yes |
AFCI | OPT |
Surge protection | Type Ⅱ, DC and AC |
STANDARD | |
Safety | IEC62109-1 / IEC62109-2 |
EMC | EN 61000-6-1 / EN 61000-6-2 / EN 61000-6-3 |
Certification | VDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / G99 / AS4777 / EN50549 / CEI 0-21 |