Small and compact size
Remote upgrade and maintenance
150% oversizing and 110% overloading
Max. DC input 14A per string
Low start-up voltage and wide MPPT range
SPD on both AC and DC side integrated
Introducing the SolaX X1-MINI G3 range of inverters, thoughtfully crafted and optimized for small PV arrays in your local region. With an impressive start-up voltage of 50V and an exceptional maximum efficiency of 98%, the X1-MINI G3 guarantees unrivaled performance, ensuring you harness the utmost energy potential from your PV system. Experience the pinnacle of efficiency and maximize your energy harvest with the SolaX X1-MINI G3, tailored specifically for your local solar needs.
Max. PV input voltage | 450V |
Max. PV input current | 14A |
No. of MPP trackers/Strings per MPP tracker | 1/1 |
Operating ambient temperature range | -25~+60°C |
Dimensions (W*H*D) | 267*328*126mm |
Net weight | 6kg |
Max. PV input voltage | 550V |
Max. PV input current | 14A |
No. of MPP trackers/Strings per MPP tracker | 1/1 |
Operating ambient temperature range | -25~+60°C |
Dimensions (W*H*D) | 267*328*126mm |
Net weight | 8.3kg |
10s data refresh on SolaX Cloud
I-V curve diagnosis
Supports parallel operation for up to 5 inverters, no external EMS required
Smart loads management (e.g., heat pump, smart EV charger)
200% PV oversizing and 16A input to support
High-power panels
Ultra-Wide MPPT voltage range
Global MPP tracking with shade optimization
Type II SPD on AC&DC side
Ready for Rapid Shutdown function
AFCI support (optional)
Built-in export control function
Unleash the full potential of the X1-MINI G4 inverter and revolutionize your solar journey with an impressive start-up voltage of 50V. Experience unmatched performance with 200% oversizing capability, a wide MPPT voltage range, and global MPP scan. Enjoy enhanced monitoring, advanced safety features, and seamless adaptability for home EV charger solutions. Expand effortlessly with Datahub and Modbus integration. Achieve maximum energy potential and unrivaled efficiency in an inverter even smaller than an A4 paper, perfectly suited for balcony installations. Empower yourself with the X1-MINI G4 and embrace the power of solar like never before.
Parameter | X1-MINI-0.6K-G4 |
Max. recommended PV array power | 1.2 |
Max. PV input voltage | 450 |
Nominal PV input voltage | 360 |
Operating voltage range | 35 ~ 450 |
MPPT voltage range | 40 ~ 450 |
Start-up voltage | 50 |
No. of MPP trackers / Strings per MPP tracker | 1 / 1 |
Max. input current per MPPT | 16 |
Max. input short circuit current per MPPT | 22 |
Rated output power | 600 |
Rated output current | 2.6 |
Max. output apparent power | 600 |
Max. output continuous current | 3 |
Nominal AC voltage | 1 / N / PE, 220 / 230 / 240 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
Parameter | X1-MINI-0.7K-G4 |
Max. recommended PV array power | 1.4 |
Max. PV input voltage | 450 |
Nominal PV input voltage | 360 |
Operating voltage range | 35 ~ 450 |
MPPT voltage range | 40 ~ 450 |
Start-up voltage | 50 |
No. of MPP trackers / Strings per MPP tracker | 1 / 1 |
Max. input current per MPPT | 16 |
Max. input short circuit current per MPPT | 22 |
Rated output power | 700 |
Rated output current | 3.1 |
Max. output apparent power | 770 |
Max. output continuous current | 3.5 |
Nominal AC voltage | 1 / N / PE, 220 / 230 / 240 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
Parameter | X1-MINI-0.8K-G4 |
Max. recommended PV array power | 1.6 |
Max. PV input voltage | 450 |
Nominal PV input voltage | 360 |
Operating voltage range | 35 ~ 450 |
MPPT voltage range | 40 ~ 450 |
Start-up voltage | 50 |
No. of MPP trackers / Strings per MPP tracker | 1 / 1 |
Max. input current per MPPT | 16 |
Max. input short circuit current per MPPT | 22 |
Rated output power | 800 |
Rated output current | 3.5 |
Max. output apparent power | 800 |
Max. output continuous current | 3.7 |
Nominal AC voltage | 1 / N / PE, 220 / 230 / 240 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
Parameter | X1-MINI-1.1K-G4 |
Max. recommended PV array power | 2.2 |
Max. PV input voltage | 450 |
Nominal PV input voltage | 360 |
Operating voltage range | 35 ~ 450 |
MPPT voltage range | 40 ~ 450 |
Start-up voltage | 50 |
No. of MPP trackers / Strings per MPP tracker | 1 / 1 |
Max. input current per MPPT | 16 |
Max. input short circuit current per MPPT | 22 |
Rated output power | 1100 |
Rated output current | 4.8 |
Max. output apparent power | 1210 |
Max. output continuous current | 5.5 |
Nominal AC voltage | 1 / N / PE, 220 / 230 / 240 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
Parameter | X1-MINI-1.5K-G4 |
Max. recommended PV array power | 3 |
Max. PV input voltage | 550 |
Nominal PV input voltage | 360 |
Operating voltage range | 35 ~ 550 |
MPPT voltage range | 40 ~ 550 |
Start-up voltage | 50 |
No. of MPP trackers / Strings per MPP tracker | 1 / 1 |
Max. input current per MPPT | 16 |
Max. input short circuit current per MPPT | 22 |
Rated output power | 1500 |
Rated output current | 6.5 |
Max. output apparent power | 1650 |
Max. output continuous current | 7.5 |
Nominal AC voltage | 1 / N / PE, 220 / 230 / 240 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
Parameter | X1-MINI-2.0K-G4 |
Max. recommended PV array power | 4 |
Max. PV input voltage | 550 |
Nominal PV input voltage | 360 |
Operating voltage range | 35 ~ 550 |
MPPT voltage range | 40 ~ 550 |
Start-up voltage | 50 |
No. of MPP trackers / Strings per MPP tracker | 1 / 1 |
Max. input current per MPPT | 16 |
Max. input short circuit current per MPPT | 22 |
Rated output power | 2000 |
Rated output current | 8.7 |
Max. output apparent power | 2200 |
Max. output continuous current | 10 |
Nominal AC voltage | 1 / N / PE, 220 / 230 / 240 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
Parameter | X1-MINI-2.5K-G4 |
Max. recommended PV array power | 5 |
Max. PV input voltage | 550 |
Nominal PV input voltage | 360 |
Operating voltage range | 35 ~ 550 |
MPPT voltage range | 40 ~ 550 |
Start-up voltage | 50 |
No. of MPP trackers / Strings per MPP tracker | 1 / 1 |
Max. input current per MPPT | 16 |
Max. input short circuit current per MPPT | 22 |
Rated output power | 2500 |
Rated output current | 10.9 |
Max. output apparent power | 2750 |
Max. output continuous current | 12.5 |
Nominal AC voltage | 1 / N / PE, 220 / 230 / 240 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
Parameter | X1-MINI-3.0K-G4 |
Max. recommended PV array power | 6 |
Max. PV input voltage | 550 |
Nominal PV input voltage | 360 |
Operating voltage range | 35 ~ 550 |
MPPT voltage range | 40 ~ 550 |
Start-up voltage | 50 |
No. of MPP trackers / Strings per MPP tracker | 1 / 1 |
Max. input current per MPPT | 16 |
Max. input short circuit current per MPPT | 22 |
Rated output power | 3000 |
Rated output current | 13.1 |
Max. output apparent power | 3300 |
Max. output continuous current | 15 |
Nominal AC voltage | 1 / N / PE, 220 / 230 / 240 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
Parameter | X1-MINI-3.3K-G4 |
Max. recommended PV array power | 6.6 |
Max. PV input voltage | 550 |
Nominal PV input voltage | 360 |
Operating voltage range | 35 ~ 550 |
MPPT voltage range | 40 ~ 550 |
Start-up voltage | 50 |
No. of MPP trackers / Strings per MPP tracker | 1 / 1 |
Max. input current per MPPT | 16 |
Max. input short circuit current per MPPT | 22 |
Rated output power | 3300 |
Rated output current | 14.4 |
Max. output apparent power | 3300 |
Max. output continuous current | 15 |
Nominal AC voltage | 1 / N / PE, 220 / 230 / 240 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency range | 50 ± 5 Hz / 60 ± 5 Hz |
Adjustable Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |